SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1041 • October 2007
Identifying Permanent Memory in a Target Board
1. Log in to XSCF.
2. Execute the following command:
The following example shows a display of the showdevices -d command where 0
is the domain_id.
is the domain_id.
The entry for column 4 perm mem MB indicates the presence of permanent memory
if the value is non-zero.
if the value is non-zero.
The example shows permanent memory on 00-2, with 1674 MB.
If the board includes permanent memory, when you execute the deleteboard
command or the moveboard command, the following notice appears:
command or the moveboard command, the following notice appears:
XSCF> showdevices -d
domain_id
XSCF> showdevices -d 0
...
Memory:
-------
board perm base domain target deleted remaining
DID XSB mem MB mem MB address mem MB XSB mem MB mem MB
00 00-0 8192 0 0x0000000000000000 24576
00 00-2 8192 1674 0x000003c000000000 24576
00 00-3 8192 0 0x0000034000000000 24576
...
System may be temporarily suspended, proceed?
[y|n]: