4.3 TROUBLESHOOTING GUIDE
In general, possible trouble is classified in two kinds.
The one is called Starting Failure which is caused from an electrical defect. The other is Ineffective Air
Conditioning 
caused by a defect in the refrigeration circuit and improper application.
Unit runs but poor cooling is ineffective.
Ineffective Cooling 
Check of outdoor coil
(heat exchanger) & fan
operation.
Check gas leakage.
Repair gas leak.
Replacement of unit if the
unit is beyond repair.
Satisfactory operation with
temperature difference of
inlet & outlet air ; 
44~50
°
F(7~10
°
C) 
Check heat load 
increase.
Clean condenser.
Not on separate circuit
Check inside gas
pressure.
Adjusting of refrigerant
charge
Malfunction of compressor
Replacement of
compressor
Check of cold  air circulation
 for smooth flow.
Dirty indoor coil
(Heat exchanger)
Remove obstruction.
Check clogging in 
refrigeration circuit.
Repair clogging in 
refrigeration circuit.
Obstruction at air outlet
Clogged of air filter
Malfunction of fan