Furuno navnet gd-1920c Manual De Usuario

Descargar
Página de 239
7. CUSTOMIZING YOUR UNIT 
 
7-13
7.4 Chart 
Setup 
This paragraph shows you how to setup digital charts, from offsetting chart position to 
turning chart attributes on or off. 
 
7.4.1 Chart 
offset 
In some instances position may be off by a few seconds. For example, the position of the 
ship is shown to be at sea while it is in fact moored at a pier. You can compensate for this 
error by offsetting chart position as shown in the procedure below. 
 
1.  Show the plotter display, then press the 
MENU key followed by the CHART SETUP and 
CHART OFFSET soft keys. 
+
SET
OFFSET
RESET
OFFSET
RETURN
BRIDGE
FISH
WP-002
  34
°
 22. 3456'N        353.9
°
M
    
TRIP NU
080
°
 22. 3456'E         0.75nm              9.9 nm
CHART
 OFFSET
+
16.0nm
 
Plotter display, chart offset selected 
2. Use the 
Trackball to place the cursor at the correct latitude and longitude position of 
own ship. 
3.  Press the SET OFFSET soft key. 
4. Press the 
MENU key to close the menu. The “chart offset icon” ( ) appears at the top of 
the display. 
 
To cancel chart offset, press the RESET OFFSET soft key at step 3 in the above 
procedure.