Furuno navnet gd-1920c Manual De Usuario

Descargar
Página de 239
8. MAINTENANCE, TROUBLESHOOTING 
 
8-3
8.4 Replacing 
the 
Magnetron 
When the magnetron has expired, distant targets cannot be seen on the display. When you 
feel that long range performance has decreased, contact a FURUNO agent or dealer about 
replacement of the magnetron. 
 
Radar model and magnetron used 
Model Magnetron 
Type 
Code 
No. 
MODEL 1824C 
E3588 
000-146-866 
E3571 000-146-867 
MG4004 000-158-895 
MODEL 1834C 
MODEL 1934C 
MAF1421B 000-158-786-10 
000-146-871 
MAF1422B 
000-158-788-10 
MODEL 1944C 
MG4006 000-158-896 
MODEL 1954C 
MAF1425B 
000-158-790-10 
MODEL 1964C 
M1458F 
000-158-780-10 
 
8.5  Replacing the Synchro Belt (1824C only) 
When the synchro belt of MODEL1824C has worn out, the sweep is not synchronized with 
antenna rotation, which results in an abnormal picture. 
 
When you suspect that the synchro belt has worn out, contact a FURUNO agent or dealer 
about replacement. (Type: 40 S2M 266UG, Code No.: 000-808-743) 
 
 
8.6 Trackball 
Maintenance 
If the cursor skips or moves abnormally, you may need to clean the Trackball
   
1.  Turn the retainer ring counterclockwise 45° 
to unlock it. 
2.  Remove the retainer ring and ball. 
3.  Clean the ball with a soft lint-free cloth, and 
then blow carefully into the ball-cage to 
dislodge dust and lint. 
4.  Look for a build-up of dirt on the metal 
rollers. If dirty, clean the rollers using a cotton swab moistened lightly with 
isopropyl-rubbing alcohol. 
5.  Make sure that fluff from the swab is not left on the rollers. 
6.  Replace the ball and retainer ring. Be sure the retainer ring is not inserted reversely. 
 
Note: 
Trackball maintenance parts are available as below. 
 
Part Type 
Code 
No. 
Retainer ring and ball 
MU3721 
000-144-645 
Retainer Ring