Citizen CT-S2000DCL Manual De Usuario

Descargar
Página de 156
— 15 —
80 
mm
58mm
60mm
InitialSettings
1
Communication condition DIP switch setting
Memory switch
OFF
setting method
setting
2
Hand shake
XON/XOFF
DTR/DSR
OFF
3
Bit length
7 bits
8 bits
OFF
4
Parity check
With parity
None
OFF
5
Parity selection
Even parity
Odd parity
OFF
6
ON
7
ON
8
INIT
Reset
Invalid
OFF
3.6  Setting DIP Switch
CAUTION!
When setting the partition to the slot for 58 mm or 60 mm paper roll, be sure not to set
it slanted.
DIP switch
Interface board
mounting screws
CAUTION!
When setting the DIP switch, DO NOT remove screws other than those for mounting
the serial interface board.
The DIP switch is present on the serial interface
board.
Remove the board fixing screws, take out the
interface board, and then set the DIP switch. The
function of each switch is as shown below.
3.5  Partition for Paper Roll
Selecting baud rate
Switch No.
6
7
2400
OFF
OFF
4800
ON
OFF
9600
OFF
ON
19200
ON
ON
1200, 38400, 57600 and 115200 bps can also be selected by a command, etc.
Switch No.
Function
ON
OFF
Baud rate selection
See Table below.
Baud Rate (bps)
Partition
At the time of shipment, this partition is set to “80-mm
wide roll paper position”.
1.
Confirm that the power switch is OFF.
2.
Open the printer cover.
3.
Set the partition to each to the slot which
meets the width of the paper roll used. When
using the 83-mm wide paper roll, remove the
partition.
4.
Change the setting of paper width by reffering
to the section 5.2, "Manual Setting of Memory
Switch".