Zebra 49834 Manual De Usuario

Descargar
Página de 396
Troubleshooting
Print Engine Diagnostics
57518L-001 Rev. A
3/18/05
170PAX4 Maintenance Manual
121
FEED and PAUSE Self Test
Performing this self test temporarily resets the print engine configuration to the factory default 
values. These values are active only until power is turned off unless you save them 
permanently in memory. If the factory default values are permanently saved, a media 
calibration procedure must be performed, and you must reset the head resistance value and the 
applicator port setting to their required values.
To perform a FEED and PAUSE self test, complete these steps:
1.
Turn Off (O) the print engine.
2.
Press and hold FEED and PAUSE
 
while turning the power On (I). Hold FEED and 
PAUSE
 until the DATA light turns off.
The print engine configuration is temporarily reset to the factory default values. No labels 
print at the end of this test.
 indicates which print engine function controls each of the configuration parameters:
Table 17 • Control of Parameters
Parameter
Controlled By
Darkness
Configuration, ZPL
Tear Off
Configuration, ZPL
Print Mode
Configuration, ZPL
Media Type
Calibration, Configuration, ZPL
Sensor Type
Configuration, ZPL
Print Method
Calibration, Configuration, ZPL
Print Width
Configuration, ZPL
Label Length
Calibration, Configuration, ZPL
Maximum Length
Configuration and Memory Size
Host Port
Configuration
Baud
Configuration, ZPL
Data Bits
Configuration, ZPL
Parity
Configuration, ZPL
Stop Bits
Configuration, ZPL
Host Handshake
Configuration, ZPL
Protocol
Configuration, ZPL
Network ID
Configuration, ZPL
Communications
Configuration, ZPL
Control Prefix
Configuration, ZPL