Preventive and Corrective Maintenance
Printed Circuit Boards—Ribbon Tension Control Board
57518L-001 Rev. A
3/18/05
170PAX4 Maintenance Manual
259
Ribbon Tension Control Board
This procedure is for installing or replacing the ribbon tension control board. Read these 
instructions thoroughly before performing this procedure.
Tools Required
Installation Instructions
Refer to 
 and remove the print engine from the applicator.
Remove the Ribbon Tension Control Board
1.
. Locate the ribbon tension control board on the back wall of the electronics 
enclosure.
2.
Disconnect all the cables from the ribbon tension control board. 
3.
Remove the four hex screws, the cable clamp, and the ribbon tension control board.
Caution • A qualified service technician must perform this installation.
‰ Screwdriver, Phillips No. 1, Extended 
Reach (10 in. shaft), Magnetic
‰ Metric Hex Key (Allen Wrench) Set
Note • 
Be sure to note the location of all cables and the cable clamp for your print engine.