Chapter 9
VirtualBench-DIO
©
 National Instruments Corporation
9-3
Getting Started with VirtualBench
c.
Select the Device and SCXI Module that you want to use. The 
SCXI Module list is disabled if no SCXI modules are 
configured for the selected device. The device must be 
successfully configured in the NI-DAQ Configuration Utility 
to appear in this list.
d.
Click on the Ports tab in the DIO Settings dialog box.
e.
Select the preferred Port Direction, Inversion, and Initial 
Output State for every port in the Port list.
f.
Click on OK to use these settings.
2.
Use the Port Control to assign a digital port from your DAQ 
device to that particular port control group.
3.
Change the output state of a particular port by selecting or 
deselecting the On/Off buttons or Hex control to the preferred state 
and finally clicking on the Write button to change the port to the 
new state.
4.
Read the states displayed on the LEDs. If the port is configured as 
input, no additional settings are needed. 
Note:
Please refer to the VirtualBench-DIO Online Help for additional help on 
configuring VirtualBench-DIO for your specific application.