2.1.3 SUSPENDED 
MOUNTING
If planning to suspend the generator below the horizontal sup-
port tubing, the suspension method to use with the vehicle frame 
members must (a) be able to support the weight of the generator 
AND (b) provide sufficient restraint for the generator. One typical 
suspended mounting system is shown in Figure 2.2. The location 
of a suspended mounting system must be carefully planned, keep-
ing the following general rules in mind:
Protect the generator against road splash and debris. Baffles or 
• 
splash guards may be required to protect certain areas of the 
generator. To make sure the generator is adequately protected, 
road test the installation through mud, water and slush.
Figure 2.2 – Typical Suspended Mounting System
The installer must make certain that the selected location will 
• 
permit adequate cooling and ventilating airflow to be supplied.
2.1.4 GENERATOR 
RESTRAINT
Use four 3/8"-16 hardened steel bolts (Grade 5) to fasten the 
generator to the supporting frame or the support tubing. These 
bolts must pass through (a) the generator mounting base, (b) the 
compartment floor (if a compartment is used) and (c) the support-
ing framework (Figure 2.3). All bolts must be long enough so that 
when tight, at least three threads are visible past the retaining lock 
nuts. Refer to "Generator Compartments" for the location of the 
generator mounting holes. Torque Bolts to 31 ft./lbs..
Figure 2.3 – Typical Generator Restraint
2.2   GENERATOR COMPARTMENTS
Whether the generator set is being installed inside a compartment 
specifically manufactured to house a generator or inside a compart-
ment that the installer constructs, the compartment MUST meet 
certain specifications as outlined in the following sections:
2.2.1 COMPARTMENT 
SIZE
Plan the compartment size carefully. Provide a minimum clearance 
of 1/2 inch (13 mm) on the front top, sides, and from the back for 
air circulation AFTER the compartment has been lined with metal 
and sound insulation (Figure 2.4).
NOTE:
Refer to “Figure 1.2 – Major Features and Dimensions”.
Figure 2.4 – Clearances
1/2" Clearance
in Back
1/2" Clearance on Top
1/2" Each Side
1/2"
in Front
Insulation
Plywood
Compartment
18" Clearance Recommended
Belo
w (Minim
um 12")
2.2.2 COMPARTMENT 
CONSTRUCTION
The generator compartment should be either constructed of, or 
• 
lined with, 26-gauge galvanized steel.
NOTE:
Aluminum is NOT an acceptable alternative to galvanized steel 
due to aluminum’s low melting point.
If the compartment is lined with galvanized steel, it may be 
• 
constructed of any material. The manufacturer recommends 
that the compartment be constructed of 1/2-inch thick plywood 
(not strandboard), with the floor made of a double thickness of 
1/2-inch plywood with the grain of the wood at cross section 
for added strength (Figure 2.5).
If constructing a compartment, line the exterior (underside) of 
• 
the compartment floor with 26-gauge galvanized steel.
All seams, splices and joints of the compartment walls (unless 
• 
vapor tight by design) should be caulked to prevent poison-
ous, flammable or explosive vapors from entering the vehicle 
interior.
Installation