caddx nx-4 Manual

Descargar
Página de 18
6
Ready Light
The 
ready light
 is “on” when the system is ready to arm and “flashes” if ready to
force arm. The 
ready light
 is off when the system is not ready to arm because
of a zone(s) being faulted.
Stay Light
The 
stay light 
is “on” when the all interior (motion detector) zones are
bypassed.
Zone Light
The 
zone lights
 are “off” when everything is normal. A 
zone light
 will be “on” if
the zone has been bypassed. If a 
zone light
 is “flashing”, that zone is in alarm
or has been faulted. If a 
zone light
 is “flashing” rapidly, it means that the zone is
in a trouble condition.   Trouble conditions are:
ƒ
 
Tamper
ƒ
 
Hardware
ƒ
 
Low Battery
ƒ
 
Loss of Supervision
(A combination of Alarm/Fault and Tamper/Trouble will produce a rapid
“flashing” light for a short period of time, followed by a slow “flashing” light.)
EMERGENCY ACTIVATION KEYS
NOTES: You must press and hold these keys for 2 seconds to activate
these functions.   Your system may not be programmed for these activation
keys (see page 1)
You should press these keys only in an emergency situation
that requires response by emergency personnel.   If your system is programmed
for these functions, the following reports can be sent.
Fire Key – This key can activate the fire alarm when pressed for two seconds. If
your system is connected to a monitoring center, an emergency report could be
sent to that center.
Auxiliary Emergency Key – This key can activate the auxiliary alarm when
pressed for two seconds. If your system is connected to a monitoring center, an
emergency report could be sent to that center.
Police (Panic/Hold-Up) Key - This key can sound a local audible alarm when
pressed for two seconds. If your system is connected to a monitoring center, an
emergency report could be transmitted to that center.  NOTE: Some Panic/Hold-
Up alarms are programmed to be silent at the protected site while reporting an
alarm to the monitoring center. Check with your installing company to determine
how your security system will respond to the Panic/Hold-Up activation.