AC Volt
Range
Resolution
Max Display
Accuracy
3V
1mV
3.000
±(1.3% +5)
40Hz to 500Hz
30V
10mV
30.00
±(1.3% +5)
300V
100mV
300.0
40Hz to 1kHz
750V
1V
750
AC Conversion Type: Average Sensing RMS indication.
Input Impedance: 10M
Ω
less tan 100PF.
To Measure True RMS AC Voltage:
1.  Plug the black test lead into the COM port and the red test 
lead into the V
Ω
Hz port.
2.  Set the rotary switch to the V position.
3.  Push the blue button until 
AC
is shown on the display.
4.  Connect the meter in parallel with the load or circuit.
5.  Measure AC Voltage.
Overload Protection
Function
Overload Protection
VAC & VDC
1000V
AAC & ADC
1A/500V
10A/500V
Ohms (
Ω
)
600VAC/600VDC
Diode
600VAC/600VDC
Continuity
600VAC/600VDC
Unit of Measure Multipliers
For your reference, the following symbols are often used to
make measurement easier:
Symbol
Verbal
Multiplier
M
mega
x 1,000,000
k
kilo
x 1,000
m
milli
÷ 1,000
µ
micro
÷ 1,000,000
Auto Power Off (APO)
The APO sign on the LCD panel indicates the meter is working
in the Auto Power Off mode. If the meter idles for more than 10
minutes, the meter automatically turns the power off. When this
happens, the state of the meter is saved the meter can be
turned back on by pushing any key switch or changing the
rotary mode. The meter will give an alarm 15 seconds before
the meter automatically turns the power off.  To disable the auto
power off function, power-up the meter while pressing either
the range or      Hz switch.
Hz sensitivity
The sensitivity in the     Hz mode (pushing key) is 1/10 of full
scale range. The accuracy is same as Frequency mode. The
measuring frequency is from 40Hz up to 1KHz.
APO RPM
Hz
˜
Circuit Connection:
˜
˜
˜
5