E-Mu orbit v2 Manual De Usuario

Descargar
Página de 140
Chapter 5: Edit Menu
67
• Crossfade Amount
The crossfade amount parameter determines the range over which
crossfading will occur. Crossfade amount is variable from 000 to 255.
The larger the value, the more modulation will be required to effect a
complete crossfade.
XFADE AMOUNT
128
• Cross-switch Point
The cross-switch point determines the point at which cross-switching
will occur when key position or velocity is controlling cross-switch.
SWITCH POINT
064  (E3)
• Primary Filter Type
This function selects the type of filter for the primary layer. 17 differ-
ent filter types are provided. If no filtering is desired, you can bypass
the filter by turning it Off.
FILTER TYPE  pri
2 Pole Lowpass
FILTER TYPES
2-pole Lowpass
Lowpass filter with 12dB/octave rolloff and Q control.
4-pole Lowpass
Lowpass filter with 24dB/octave rolloff and Q control.
6-pole Lowpass
Lowpass filter with 36dB/octave rolloff and Q control.
2nd Order Highpass
Highpass filter with 12dB/octave rolloff and Q control.
4th Order Highpass
Highpass filter with 24dB/octave rolloff and Q control.
EDIT MENU
 To enable the cross-switch
function, you must assign
Crossfade to a modulation
source in the Realtime or
Key/Velocity Modulation
screen.
Velocity
Key