efd 736hpa Guía Del Usuario
O-ring
#7519
#7519
Air cylinder
body #73602
body #73602
Fluid body
#73608
#73608
Outlet cap
#73609
#73609
Bolts
#H10-32X1.5
#H10-32X1.5
Upper seal
#73507-1 (Hytrel
#73507-1 (Hytrel
®
)
#73507V-1 (Viton
®
)
Lower seal
#73507-1 (Hytrel
#73507-1 (Hytrel
®
)
#73507V-1 (Viton
®
)
Split washer
#HW10
#HW10
1
2
5
8
7
12
13
To replace the lower seal:
1. Remove the three bolts from the
outlet cap.
2. Remove the outlet cap.
3. Pry the seal out of the outlet cap
using a small screwdriver.
4. Clean the seal cavity and then press
a new seal into the cavity. Insert
tapered end first, so that the O-ring
faces up.
tapered end first, so that the O-ring
faces up.
5. Inspect the fluid body O-ring and
replace if necessary.
6. Reinstall the outlet cap. Tighten the
three bolts to 30 to 35 inch pounds.
To replace the upper seal:
7. Remove the three bolts from the
outlet cap.
8. Remove the outlet cap and fluid
body.
9. Pry the seal out of the fluid body
using a small screwdriver.
10. Clean the seal cavity and then
press a new seal into cavity. Insert
seal with O-ring facing inside the
fluid body.
seal with O-ring facing inside the
fluid body.
11. Reinstall the outlet cap and fluid
body. Tighten the three bolts to
30 to 35 inch pounds.
30 to 35 inch pounds.
To replace air cylinder seals:
12. Remove the three bolts from the
outlet cap.
13. Remove the outlet cap and fluid
body.
14. Unscrew the adjustable stroke air
cap.
15. Remove the piston-and-spool
assembly and the piston return
spring.
spring.
www.efd-inc.com info@efd-inc.com
USA 800-556-3484 Europe +44 (0) 1582 666334 Asia +86 (21) 5854 2345
Sales and service of EFD dispensing systems are available worldwide.
Valve Disassembly and
Reassembly Procedures
Reassembly Procedures