Gap defines the gap between the insulation bridges on a thermal sym-
bol. The specification is made as a % of the hole diameter, and is con-
strained by maximum and minimum values.
The Isolate values for Thermal and Annulus determine the width of the
thermal bridge or ring.
The Restring option determines whether the insulation bridge of the
thermal symbol should be drawn immediately at the edge of the hole or
at a distance from the hole given by the restring value (Restring tab, In-
ner setting).
If the Restring option for Annulus is deactivated, a filled circle is gener-
ated instead of the annulus ring. This is the default setting.
The isolate value for Thermal also applies to polygons. It determines the
distance between a polygon and the restring of the pad or via that is
joined to the polygon through a thermal symbol.
The Generate thermals for vias flag permits thermal symbols at through-
hole contacts. Otherwise vias are fully connected to the copper plane.
This applies also for polygons. But you can disable this option for indi-
vidual polygons (CHANGE THERMALS OFF).
Calculations for automatically created symbols in supply layers:
Annulus:
Inner diameter = pad hole diameter + 2 * restring
Outer diameter = max(pad-hole diameter, inner diameter)
+ 2*isolate
Default: restring = 0 (fully filled), isolate = 20 (mil).
Thermal:
Inner diameter = pad hole diameter + 2 * restring
Outer diameter = inner diameter + 2 * isolate
Isolate
Gap
Restring
Pads or smds marked with the flag NOTHERMALS (resp. CHANGE
THERMALS OFF) in the Package Editor will be connected basically
without thermal symbols.
105