cadsoft eagle 4.5 Manual De Usuario

Descargar
Página de 248
DRC error list in the Layout Editor
Signal layers which are not visible (DISPLAY command) will not be
checked by the Design Rule Check!
Error messages and their meaning
Angle:
Tracks are not laid in an angle of 0, 45, 90 or 135°. This check can be
switched on or off in the Design Rules (Misc tab).
Default: off.
Blind Via Ratio:
The limit of the ratio of depth to drill diameter is exceeded. In this case
you have to adjust the via's drill diameter (see Design Rules, Sizes tab).
Clearance:
Clearance violation between copper elements. The settings of the De-
sign Rules' Clearance tab and the value for Clearance of a given net class
will be checked. In addition the Isolate value will be taken into conside-
ration for polygons with the same rank and polygons which are defined
as part of a package.
To deactivate the clearance check between elements that belong to the
same signal, use the value 0 for Same signals in the Clearance tab.
Dimension:
Distance violation between smds, pads, and connected copper objects
and a dimension line (drawn in Layer 20, Dimension), like the board's
outlines. Defined through the value for Copper/Dimension in the
118