Wiring the Schematic Diagram
Draw Nets (NET)
The NET command defines the connections between the pins. Nets be-
gin and end at the connection points of a pin. This is visible when layer
93, Pins, is displayed (DISPLAY command).
Nets are always given an automatically generated name. This can be
changed by means of the NAME command. Nets with the same name
are connected to one another, regardless of whether or not they appear
continuous on the drawing. This applies even when they appear on dif-
ferent sheets.
If a net is taken to another net, a bus, or a pin connecting point, the net
line ends there and is connected. If no connection is made when the net
is placed, the net line continues to be attached to the mouse. This behav-
ior can be changed through the Options/Set/Misc menu (using the Auto
end net and bus option). If this option is deactivated, a double click is
needed to end a net. Nets are shown on layer 91, Nets.
Nets must end exactly at a pin connecting point in order to be joined. A
net is not joined to the pin if it ends somewhere on the pin line.
EAGLE will inform you about the resulting net name or offer a selec-
tion of possible names if you are connecting different nets.
The JUNCTION command is used to mark connections on nets that
cross one another. Junctions are placed by default. This option, (Auto set
junction), can also be deactivated through the Options/Set/Misc menu.
Nets must be drawn with the NET command, not with the WIRE
command.
Do not copy net lines with the COPY command. If you do this, the
new net lines won’t get new net names. This could result in unwanted
connections.
If the MOVE command is used to move a net over another net, or over
a pin, no electrical connection is created. To check this, you can click the
net with the SHOW command. All the connected pins and nets will be
highlighted. If a gate is moved, the nets connected to it will be dragged
along.
An identifier can be placed on a net with the LABEL command. Pro-
vided you have defined an alternative grid, labels can be arranged com-
fortably in a finer grid with the Alt key pressed.