ge-interlogix simon 3 Manual De Usuario

Descargar
Página de 68
Simon Security System
41
Programming System Access Codes
Utility Access Code 1 (Dealer Code)
Depending upon how Option 54 is set, the default utility access code is 654321, 54321, 
4321 (factory default), or 321. This code can be used for all programming.
Utility Access Code 2 (Installer Code)
Depending upon how Option 54 is set, the default access code is 654321, 54321, 4321 
(factory default), or 321. This code is limited to changing all but the following: Utility 
Access Code 1, Options 4, 5, 6, 8, 9, 12, 13, 54, and 69.
Master Access Code
Depending upon how Option 54 is set, the default Master Access Code is 123456, 
12345, 1234 (factory default), or 123. This code is used to: disarm the panel, subdisarm 
the panel, program light control, set the system clock, program the master code, pro-
gram access codes 1-5, program the panic code, perform a sensor or phone test, and pro-
gram options 1, 2, 3, 31, 36, 37, 41, 42, 43, 55, 81 and 82.
Access Codes (1 - 5)
The panel can have up to 5 secondary user access codes. These could be used by chil-
dren, a baby sitter, or a service person to disarm (or arm if Option 60 is on). These codes 
cannot be used for programming.
Panic Code
The Panic Code is able to arm, disarm, or subdisarm the panel and send a silent alarm to 
the Central Station. There will be no indication of an alarm at the panel
¾
To add a code:
1.
Press Add.
2.
Press Access Code button. Continue pressing this button until you hear the access 
code to be changed.
3.
Press DONE.
4.
Enter the new access code by using the numbered keys. The panel announces the 
new code.
¾
To delete a code:
1.
Press Delete.
2.
Press Access Code. Continue pressing this button until you hear the access code to 
be deleted.
3.
Press DONE. The panel announces the code is deleted.
Testing the 
System
This section describes how to perform the following test procedures:
Control Panel
Testing sensors
Testing phone communication
Testing central station communications
Testing the X10 Lamp Modules
You should test the system after installing, after servicing, and after adding or removing 
devices from the system. 
Control Panel
Test the Control Panel by pressing the buttons as described below.
Note  
An access code is required 
when arming if Option 60: 
Secure Arming is on.
ARM Doors & Windows-The panel arms Doors & Windows. Press twice to elimi-
nate the programmed entry delay. The button will blink when No Entry Delay is on.
ARM Motion Sensors-The panel will arm Motion Sensors. Press twice to turn 
Latchkey on. The button blinks when Latchkey is on.