emium Dual
1
000-3000 V
A
Rack version
PrD 150
PrD 100
battery box
PrD 220/220er
300/300 er
For critical business continuity applications requiring
long runtimes, Premium Dual can be installed with battery
extension packs (er models) with their own internal battery
chargers to maintain sensible recharge times.
The UPS also incorporates the Riello UPS ‘power-off’ function found
in other ECO Line UPS. Premium Dual is designed to save energy
when no loads are connected.
The UPS also incorporates the Riello UPS ‘power-off’ function found
in other ECO Line UPS. Premium Dual is designed to save energy
when no loads are connected.
SimPliFieD iNStallatioN
• Tower or Rackmount UPS: Premium Dual can be installed as tower
• Tower or Rackmount UPS: Premium Dual can be installed as tower
or 19” rackmount UPS, with a front mimic panel that can be turned
through 90º to suit the installation.
through 90º to suit the installation.
• Noise Free Operation (<40dBA): the UPS can be installed in any
environment thanks to its PWM digitally-controlled high frequency
inverter.
inverter.
• High Temperature Operation: UPS components are sized for high
temperature operation up to 40ºC and are not therefore stressed
during normal operational environments.
during normal operational environments.
• EnergyShare: Premium Dual output sockets can be programmed to
disconnect less critical loads when the mains power fails.
reDuCeD maNaGemeNt CoStS
PREMiUM DUAL can be programmed remotely via software or set
manually from the front mimic panel to operate in a range of energy
saving operating modes:
• on line: maximum power protection and output voltage waveform
PREMiUM DUAL can be programmed remotely via software or set
manually from the front mimic panel to operate in a range of energy
saving operating modes:
• on line: maximum power protection and output voltage waveform
quality
• eCo: to increase operating efficiency to 98% and provide line
interactive protection
• Smart active: with the UPS selecting automatically its operating
mode - ECO or On-Line dependent upon the reliability and quality of
the local mains power supply.
the local mains power supply.
• backup: for emergencies only with the UPS only operating when
mains power fails
• Frequency converter: from 50 to 60Hz or 60 to 50Hz.
aDVaNCeD CommuNiCatioN
Premium Dual offers maximum flexibility for integrations with any
communication system.
• Multiplatform communication for all operating systems and network
Premium Dual offers maximum flexibility for integrations with any
communication system.
• Multiplatform communication for all operating systems and network
environments, Powershield
3
supervision and shut-down software included
for Windows 7, 2008, Vista, 2003, XP, Linux, Mac OS X, Sun Solaris and
VMware ESX operating systems and other Unix operating systems.
VMware ESX operating systems and other Unix operating systems.
• UPS Tools configuration and personalisation software supplied as
standard.
• RS232 serial port and opto-isolated contacts.
• USB port
• Slot for communication cards such as Modbus/Jbus, TCP/iP, SNMP
• USB port
• Slot for communication cards such as Modbus/Jbus, TCP/iP, SNMP
and relay contacts.
HiGH outPut VoltaGe Quality
• Even with distorting loads (iT loads with a crest factor of up to 3:1).
• High short circuit current on bypass.
• High overload capacity: 150% from inverter (even with no mains power).
• Filtered, stabilised, reliable (On Line double conversion technology
• Even with distorting loads (iT loads with a crest factor of up to 3:1).
• High short circuit current on bypass.
• High overload capacity: 150% from inverter (even with no mains power).
• Filtered, stabilised, reliable (On Line double conversion technology
(VFi in accordance with EN62040-2 class C1) standard with filters to
suppress atmospheric disturbances.
• Load power factor correction: incoming UPS power factor close to 1
and sinusoidal current absorption.
HiGH leVelS oF battery reliability
• Automatic and manual battery tests
• Batteries are ‘hot-swappable’ and user replaceable.
• Unlimited battery runtime extension using battery extension packs.
• Automatic and manual battery tests
• Batteries are ‘hot-swappable’ and user replaceable.
• Unlimited battery runtime extension using battery extension packs.
otHer FeatureS
• Output voltage can be selected using software (220-230-240V).
• Auto-restart when mains power returns (programmed via software)
• Stand-by on Bypass: when the machine is switched off, it
• Output voltage can be selected using software (220-230-240V).
• Auto-restart when mains power returns (programmed via software)
• Stand-by on Bypass: when the machine is switched off, it
automatically goes into bypass operation with batteries charging.
• Power-Off with zero load connected to save energy
• Low battery warning
• Power-on delay
• Full microprocessor control.
• Automatic bypass without interruption
• Status, measurements and alarms available on the front panel mimic
• Low battery warning
• Power-on delay
• Full microprocessor control.
• Automatic bypass without interruption
• Status, measurements and alarms available on the front panel mimic
panel and LCD
• UPS firmware upgrade via PC platform
• input protection including a user reset thermal switch (up to 1500VA)
• Back-feed protection
• Manual option to switch to bypass.
• input protection including a user reset thermal switch (up to 1500VA)
• Back-feed protection
• Manual option to switch to bypass.
2-year WarraNty
iNPUT
PLUG
OUTPUT
SOCKETS
iNPUT THERMAL
PROTECTiON
iNPUT
SOCKETS
EMERGENCY
SWiTCH DEViCE
(ESD)
RS232
SERiAL
USB
PORT
BATTERY
EXPANSiON
OUTLET
teCHNiCal DetailS