Panasonic CZKPU3A Guía De Operación

Descargar
Página de 2
1
Operating Instructions
Panel for Cassette (ECONAVI type)
Model No. CZ-KPU3A
Applicable indoor unit : 4-Way Cassette
Before operating the unit, read these operating instructions 
thoroughly and keep them for future reference.
Thank you for purchasing this Panasonic product.
This product is a optional of commercial air conditioner 
indoor unit.
Installation Instructions attached.
Panasonic Corporation
1006 Kadoma, Kadoma City, Osaka, Japan
CV6233335650
 
Specifi cations ....................................................................2
 
Safety Precautions ............................................................3
 
Precautions for Use ..........................................................5
 
Names of Parts ..................................................................6
• Detection Area of Sensor (Criteria) ...............................7
• How to Operate Remote Controller
(Setting Method of Each Function) ...............................8
• ECONAVI Function .........................................................9
• Direct Airfl ow and Indirect Airfl ow Function  .............11
• Circulation Function .....................................................12
• External Device Interlock Function .............................13
 
Maintenance ....................................................................14
 
Troubleshooting ..............................................................15
Contents
Product Information
If you have problems or questions concerning your Air 
Conditioner, you will need the following information. Model and 
serial numbers are on the nameplate.
Model No. 
Serial No. 
Date of purchase
Dealer’s address
Phone number
2
Specifi cations
Model Name
CZ-KPU3A
Unit Dimensions
(Width) 950mm × (Depth) 950mm × (High) 33.5mm
Net Weight
5 kg
Temperature / Humidity Range
0°C to 40°C / 20% to 80% (Indoor use only)
Power Source
DC16 V (Supplied from indoor unit)
Panasonic Corporation
Website: http://www.panasonic.com
Printed in JAPAN
© Panasonic Corporation 2016
85464609363000
DC0816-0
Authorised representative in EU
Panasonic Testing Centre 
Panasonic Marketing Europe GmbH 
Winsbergring 15, 22525 Hamburg, Germany
3
Safety Precautions
Confi rm to authorized dealer 
or specialist on usage of 
specifi ed refrigerant type. Using 
of refrigerant other than the 
specifi ed type may cause product 
damage, burst and injury etc.
Do not use ECONAVI function 
when only a disabled person 
or infant staying at home. If a 
small movement of human body 
continues for a long time, Panel 
for cassette (ECONAVI type) 
recognizes human absence and  
air conditioner may sometimes 
stop operating. 
Do not use this appliance in a 
potentially explosive atmosphere.
Never touch the unit with wet hands.
Do not insert your fi ngers or 
other objects into the air 
conditioner indoor or 
outdoor unit, rotating parts may 
cause injury.
If the refrigerant comes in contact
with a fl ame, it produces a toxic 
gas.
For safety, be sure to turn the 
air conditioner off and also to 
disconnect the power before 
cleaning or servicing.
Pull off the power plug from 
a receptacle, or switch off 
the breaker, or switch off the 
power disconnecting mean to 
isolate the air conditioner from the 
main power supply in case of 
emergency.
Do not clean inside the indoor and 
outdoor units by users. Engage 
authorized dealer or specialist for 
cleaning.
In case of malfunction of this 
appliance, do not repair by yourself. 
Contact to the sales dealer or 
service dealer for a repair.
The following symbols used in this manual, alert you to 
potentially dangerous conditions to users, service personnel or 
the appliance:
WARNING
This symbol refers to a hazard or 
unsafe practice which can result in 
severe personal injury or death.
CAUTION
This symbol refers to a hazard or 
unsafe practice which can result 
in personal injury or product or 
property damage.
Prohibited matters
Matters to be 
observed
• Read these Operating Instructions carefully before using this 
air conditioner. If you still have any diffi culties or problems, 
consult your dealer for help.
• This air conditioner is designed to give you comfortable 
room conditions. Use this only for its intended purpose as 
described in these Operating Instructions.
WARNING
4
This appliance is intended to be used 
by expert or trained users in shops, 
in light industry and on farms, or for 
commercial use by lay persons.
This appliance is not intended for 
use by persons (including children) 
with reduced physical, sensory 
or mental capabilities, or lack of 
experience and knowledge, unless 
they have been given supervision 
or instruction concerning use of the 
appliance by a person responsible 
for their safety. Children should be 
supervised to ensure that they do 
not play with the appliance.
<for European market only>
This appliance can be used by 
children aged from 8 years and 
above and persons with reduced 
physical, sensory or mental 
capabilities or lack of experience and 
knowledge if they have been given 
supervision or instruction concerning 
use of the appliance in a safe 
way and understand the hazards 
involved. Children shall not play with 
the appliance. Cleaning and user 
maintenance shall not be made by 
children without supervision.
Keep the fi re alarm and the air outlet 
at least 1.5m away from the unit.
Do not cool or heat the room too 
much if babies or invalids are 
present.
Do not turn the air conditioner on 
and off from the power mains switch. 
Use the ON/OFF operation button.
Do not stick anything into the 
air outlet of the outdoor unit. 
This is dangerous because the 
fan is rotating at high speed.
Do not touch the air inlet or 
the sharp aluminum fi ns of the 
outdoor unit. You may get 
injured.
Do not stick any object 
into the FAN CASE. You 
may be injured and the 
unit may be damaged.
CAUTION
•   The compressor may occasionally stop during 
thunderstorms. This is not a mechanical failure. The unit 
automatically recovers after a few minutes.
•   The English text is the original instructions. Other languages 
are translation of the original instructions.
•   Do not install at the following locations.
   Humid, oily, frequent vibration, direct sunlight, nearby heat 
source, frost (Cause of trouble) 
Noise occurrence (Cause of malfunction)
•   Panel for cassette (ECONAVI type) is only for indoor use.
•   Do not scratch the surface of the sensor. (Cause of detected 
error)
•   Do not press the sensor forcibly. (Cause of damage)
•   If any heating or cooling sources exists within the detection 
area, the sensor may sometimes cannot detect correctly. 
•   Do not wipe with benzine, thinner or disposal cloth. (Cause 
of discoloration or deformation)
 
 In case of heavy dirt, mix a tiny amount of neutral 
detergent with water and soak it into a soft cloth, squeeze 
well and gently wipe off the dirt. Then, wipe with a soft dry 
cloth.
•   Do not install improper optional parts simultaneously with the 
Panel for cassette (ECONAVI type). (Cause of malfunction)
 
 See the catalogue and confi rm whether a combination use 
is valid or invalid. 
•   The movement of human body on the opposite side of the 
mirror cannot be detected. 
•   After actuation, it takes 2 to 5 minutes to verify the judgment 
of presence and absence.
NOTICE
5
Precautions for Use
Installation
 
This optional of must be installed properly by qualifi ed 
installation technicians in accordance with the Installation 
Instructions provided with the unit.
Wiring
 
All wiring must conform to the local electrical codes.
(Consult your dealer or a qualifi ed electrician for details.)
 
Each unit must be properly grounded with a ground (or 
earth) wire or through the supply wiring.
 
Wiring must be done by a qualifi ed electrician.
Operation Preparation
Turn the power mains on 5 hours before 
the start of operation.
(For warm-up)
 
Leave the power mains ON for continuous use.
ON
NOTE
Pull off the power plug from a receptacle, or switch off the 
breaker, or switch off the power disconnecting mean to isolate 
the air conditioner from the main power supply when not in use 
for a long time.
Information for Users on Collection and Disposal of 
Old Equipment and Used Batteries
T
hese symbols on the products, packaging, 
and/or accompanying documents mean that 
used electrical and electronic products and 
batteries should not be mixed with general 
household waste.
For proper treatment, recovery and recycling 
of old products and used batteries, please 
take them to applicable collection points, in 
accordance with your national legislation and 
the Directives 2002/96/EC and 2006/66/EC.
By disposing of these products and batteries 
correctly, you will help to save valuable 
resources and prevent any potential negative 
effects on human health and the environment 
which could otherwise arise from inappropriate 
waste handling.
For more information about collection and 
recycling of old products and batteries, please 
contact your local municipality, your waste 
disposal service or the point of sale where you 
purchased the items.
Penalties may be applicable for incorrect 
disposal of this waste, in accordance with 
national legislation.
For business users in the European Union 
If you wish to discard electrical and electronic 
equipment, please contact your dealer or 
supplier for further information.
[Information on Disposal in other Countries 
outside the European Union] 
These symbols are only valid in the European 
Union. If you wish to discard these items, 
please contact your local authorities or dealer 
and ask for the correct method of disposal.
Pb
Note for the battery symbol (bottom two 
symbol examples):
This symbol might be used in combination with 
a chemical symbol. In this case it complies 
with the requirement set by the Directive for 
the chemical involved.
Tips for Energy Saving
 
Avoid
 
Do not block the air intake and outlet of the unit.
(If either is obstructed, the unit will not function 
well, causing malfunction.)
 
During cooling operation, use sunshades, blinds or 
curtains to prevent direct sunlight from entering the 
room.
 
Do
 
Always keep the air fi lter clean.
(A clogged fi lter will impair the performance of the 
unit.)
→ “Maintenance” (P.14)
 
To prevent conditioned air from escaping, keep 
windows, doors and any other openings closed.
6
Names of Parts 
 
Panel for Cassette 
(ECONAVI type)
Flap
(4 locations)
Air intake grille
(air intake)
Air outlet
(4 locations)
Floor Temperature Sensor
  Detects average temperature 
of fl oor surface.
Human Detection Sensor
   Detects human movement. 
NOTE
  
Since the Human Detection Sensor enables to detect the heat transfer, it can not only detect human but it can 
detect coexisting high-temperature objects.
  (For example, movement of animals, swinging head freestanding type infrared heater, etc.)
 
 The
 
Human Detection Sensor cannot detect human presence in some cases listed below.
 
• 
In case of less human movement
 
• 
In case of less exposure of the skin
 
• 
In case of more than 30°C of room temperature
 
• 
In case of greasy dirt, soot, dust, scratches adhered to a surface of Human Detection Sensor
  
Since the Floor Temperature Sensor measures the average temperature of the fl oor surface in the detection area, 
there is a possibility that the sensor is infl uenced by a heat source existed in the range of the detection area. When 
taking advantage of the function with the infl uence of the fl oor temperature (circulate function), pay attention to the 
placement of a heat source. 
7
Detection Area of Sensor (Criteria)
Criteria of human detection sensor area
•  Installation height of indoor unit 2.7 m : Approx. ø7 m 
•  Installation height of indoor unit 4 m : Approx. ø8 m 
• Installation height of indoor unit 5 m : Approx. ø9 m 
Approx. ø7 - 9 m
Detection area of 
Human Detection 
Sensor
1 m above fl oor visual range
Installation 
height: 
2.7 - 5 m
Detection area of Floor Temperature Sensor
NOTE
●  The further human is away from the Human Detection Sensor, the larger the movement of human body is required 
to be detected.
●  A place where the blind angle of the Human Detection Sensor cannot detect human.
●  If there is a heat source or cooling unit in the detection area, the sensor cannot occasionally detect properly.
●  The Floor Temperature Senor detects within the sensor area of the Human Detection Sensor.
8
How to Operate Remote Controller 
(Setting Method of Each Function)
NOTE
If the Operating Instructions supplied with the remote controller in use does not give descriptions of the ECONAVI 
function, direct airflow / indirect airflow function, circulation function and external device interlock function, the in-use 
remote controller is not available to these functions.  
Refer to the Operating Instructions provided with the remote controller. 
Sample of remote control display (CZ-RTC5A) when setting the ECONAVI function: 
ECONAVI
 is displayed when setting the 
ECONAVI function.
(In case of sensor error, 
ECONAVI
 is displayed in the 
same position. See the Section “Troubleshooting” on page 
15.)
Circulation Function
Displays when setting.
Direct Airfl ow / Indirect Airfl ow Function
Displays when setting. 
Appears during circulation operation.
OI_00_281646_EN_A1.indd   1