Signal
Screensaver
Extended life settings
Input label
Off
Standby save
Off
PC Power management
Off
Auto power off
Off
OSD Language
English (UK)
Component/RGB-in select
RGB
Power save
Setup
DVI-D Power management
Off
33
Reduces power consumption
Press to select 
“Power save”
“Standby save”
“PC Power management”
“DVI-D Power management”
“Auto power off”.
Press to select “On” or “Off”.
On 
 Off
Press to exit from Setup.
1
2
3
• Power save: 
When this function is turned On, luminous level of the Plasma Display is 
suppressed, so power consumption is reduced.
• Standby save: 
When this function is turned On, power consumption of the microcomputer is 
reduced during power supply standby (see page 13, 16, 17), so standby power of 
the set is reduced.
• PC Power management: 
When this function is set to On, it operates under the following conditions to turn the 
power on or off automatically.
 
When no pictures (HD/VD sync signals) are detected for 30 or so seconds during PC 
signal input:
 
  →  Power is turned off (standby); the power indicator lights up orange.
 
When pictures (HD/VD sync signals) are subsequently detected:
 
  →  Power is turned on; the power indicator lights up green.
 
Notes:
 
• This function operates only during PC signal input.
 • 
 
This function is effective when “Sync” is set to “Auto”, “Component / RGB-in select” 
is set to “RGB” and during normal viewing (one picture screen).
• DVI-D Power management:  When this function is set to On, it operates under the following conditions to turn the 
power on or off automatically.
 
When no pictures (sync signal) are detected for 30 or so seconds during DVI signal 
input:
 
  → Power is turned off (standby); the power indicator lights up orange.
 
When pictures (sync signal) are subsequently detected:
 
  → Power is turned on; the power indicator lights up green.
 
Notes:
 
• This function operates only during DVI signal input.
 
• This function is invalid during input from DVI-D Terminal Board (TY-FB11DD).
 • 
 
Depending on the type of terminal board equipped, this function may be invalid.
• Auto power off: 
Equipment power supply is turned Off when there is no signal.
 
When this is set to On, the power supply of the unit goes Off 10 minutes after the 
input signals stop. 
 
Note:
 