CXtec NEW OEM COMPATIBLE PROCURVE 10GB SFP+SR TRANSCEIVER Guia De Especificaciones

Descargar
Página de 7
 
 
 
2  
J9150A-­‐CX  
HP  10GBASE-­‐SR  SFP+  MMF    
850NM  300M  REACH  LC  DOM  
 
 
 
Pin  Descriptions  
Pin
 
Symbol  
Name/Descriptions  
Ref.  
1  
VeeT  
Transmitter  Ground  (Common  with  Receiver  Ground).  
1  
2  
TX  Fault  
Transmitter  Fault.  LVTTL-­‐O  
2  
3  
TX  Disable  
Transmitter  Disable.  Laser  output  disabled  on  high  or  open.  LVTT-­‐I.  
3  
4  
SDA  
2-­‐Wire  Serial  Interface  Data  Line  (Same  as  MOD-­‐DEF2  in  INF-­‐8074i).  LVTTL-­‐
I/O.  
 
5  
SCL  
2-­‐Wire  Serial  Interface  Data  Line  (Same  as  MOD-­‐DEF2  in  INF-­‐8074i).  LVTTL-­‐I.  
 
6  
MOD_ABS  
Module  Absent,  Connect  to  VeeT  or  VeeR  in  Module.  
4  
7  
RS0  
Rate  Select  0,  optionally  controls  SFP+  module  receiver  LVTTL-­‐I.  
5  
8  
LOS  
Loss  of  Signal  indication.  Logic  0  indicates  normal  operation.  LVTTL-­‐O.  
2  
9  
RS1  
Rate  Select  1,  optionally  controls  SFP+  module  transmitter.  LVTTL-­‐I.  
5  
10  
VeeR  
Receiver  Ground  (Common  with  Transmitter  Ground).  
1  
11  
VeeR  
Receiver  Ground  (Common  with  Transmitter  Ground).  
1  
12  
RD-­‐  
Receiver  Inverted  DATA  out.  AC  Coupled.  CML-­‐O.  
 
13  
RD+  
Receiver  Non-­‐inverted  DATA  out.  AC  Coupled.  CML-­‐O.  
 
14  
VeeR  
Receiver  Ground  (Common  with  Transmitter  Ground).  
1  
15  
VccR  
Receiver  Power  Supply.  
 
16  
VccT  
Transmitter  Power  Supply.  
 
17  
VeeT  
Transmitter  Ground  (Common  with  Receiver  Ground).  
1  
18  
TD+  
Transmitter  Non-­‐Inverted  DATA  in.  AC  Coupled.  CML-­‐I.  
 
19  
TD-­‐  
Transmitter  Inverted  DATA  in.  AC  Coupled.  CML-­‐O.  
 
20  
VeeT  
Transmitter  Ground  (Common  with  Receiver  Ground).  
1  
 
 
Notes:  
1.  The  module  signal  ground  contacts,  VeeR  and  VeeT,  should  be  isolated  from  the  module  case.  
2.  This  contact  is  an  open  collector/drain  output  and  should  be  pulled  up  to  the  Vcc_Host  with  resister  in  
the  range  4.7KΩ  to  10KΩ.  Pull  ups  can  be  connected  to  one  or  several  power  supplies,  however  the  host  
board  design  shall  ensure  that  no  module  contract  has  voltage  exceeding  module  VccT/R  +0.5.V.  
3.  Tx_Disable  is  an  input  contact  with  a  4.7KΩ  to  10KΩ  pull-­‐up  resistor  to  VccT  inside  module.  
4.  Mod_ABS  is  connected  to  VeeT  or  VeeR  in  the  SFP+  module.  The  host  may  pull  the  contract  up  to  
Vcc_Host  with  a  resistor  in  the  range  from  4.7KΩ  to  10KΩ.  Mod_ABS  is  asserted  “High”  when  the  SFP+  
module  is  physically  absent  from  a  host  slot.