Fusion MS-AM402 Manual De Propietario

Descargar
Página de 16
Specifications
Signal to Noise 
 
 
 
>95dB
Separation   
  >60dB
Input Sensitivity 
 
 
 
300mV - 8V
LP Variable Crossover  
 
 
40Hz - 160Hz @ 18dB/octave
HP Variable Crossover 
 
 
40Hz - 600Hz @ 12dB/octave
Variable Bass Boost   
 
 
0 - + 18dB @ 45Hz
Variable Subsonic Filter 
 
 
20Hz - 55Hz @ 18dB/octave
Input Impedance 
 
 
 
20k Ω
Damping 
factor 
 
  >200
T.H.D 
 
  0.05%
Fuse Ratings 
 
 
 
1 x 25A
Dimensions(mm) 
 
 
 
229 (W) x 296(L) x 53vz(H)
12.6 Volt power output specification 
50 Watts RMS x 2 @ 4Ω 1% THD+N
96 Watts RMS x 2 @ 2Ω 1% THD+N
160 Watts RMS x 1 @ 4Ω Bridged 1% THD+N
14.4 Volt power output specification 
65 Watts RMS x 2 @ 4Ω 1% THD+N
100 Watts RMS x 2 @ 2Ω 1% THD+N
200 Watts RMS x 1 @ 4Ω Bridged 1% THD+N
010
INST
ALLA
TION
Trouble Shooting
Problem
Cause
Solution
Power LED 
not ‘ON
Fuse at battery blown 
or not installed
Replace with correct type and rated fuse. 
Improper connections
Check that the ground wire, power wire and the remote 
wires are connected to the correct terminal
Status LED 
‘ON’
Fuse blown
Replace with correct type and rated fuse.
Amplifier too hot
Move the amplifier into a more ventilated area
Speaker wires shorted
Check that there are no speaker wires shorted to any 
other wire and also check if any wire is shorted to 
ground
Internal malfunction
Disconnect all wires except ground, power and remote. Then turn the 
amplifier ’ON’, if the protection light is still ’ON’ then return for service