5  Daily Maintenance 
5.1   Regular Cleaning  
Please clean dome cover regularly to get vivid image. 
Handle the cover with care. Use water to wash.  Don’t use cloth to clean. 
Use mild detergent to clean if there is too much dust. 
Note:  
The sweat from your hand may erode plating surface, your nail may scrape dome cover result in blur 
image.
 
5.2   Problems and Solutions 
SYMPTOM 
CAUSE 
SOLUTION 
1) No self-diagnosis, 
no video signal 
when I connect 
dome to power. 
Red LED is not on. 
  Your power supplying does 
not apply to the power. Or 
connection is too loose. 
  Power off or transformer 
problem. 
  Check power is connected or 
properly earthed. 
  Check power supply condition 
or check transformer. 
Red LED light on the power 
board is on 
  Power supplying  is low 
  Something wrong with power 
board.  
  Use multimeter to check 
dome load.  
  Please contact retailer to 
replace power board.  
2) No self diagnosis. 
There is a noise  
Power supplying is inadequate. 
Replace power supplying. 
Mechanical malfunction. 
Need electrical engineer help. 
3) Video signal loss 
occurs in high speed 
rotation. 
Power supplying is not sufficient  
Replace power supplying. 
4)Video signal is not 
successive  
Circuit connection is too loose. 
Connect tightly. 
Video switch or power problem 
Need electrical engineer help. 
5) Video is not clear.  Focus is in manual mode. 
Control manually. 
Dome cover is dirty. 
Wash dome cover 
6) During camera 
switch, there is a tilt 
movement in the 
monitor. 
Camera power is not in the same 
Phase. 
When several domes are 
connected to one transformer, 
please connect the transformer 
output cable to the domes’ same 
side.