27 
7  Appendix 2 The Relationship between the 24V AC Cable 
Diameter and the Transmission Distance 
It is the recommended transmission distance when the cable diameter is fixed and the 24V AC power 
consumption is below 10%. For the AC device, the max permission voltage power consumption is 10%. 
For example, when a device of rated power 80VA installed from the transformer 35 inches (10m), then 
the min cable diameter is 0.8000mm. 
   
0.8000 
1.000 
1.250 
2.000 
10 
283 (86) 
451 (137) 
716 (218) 
1811 (551) 
20 
141 (42) 
225 (68) 
358 (109) 
905 (275) 
30 
94 (28) 
150 (45) 
238 (72) 
603 (183) 
40 
70 (21) 
112 (34) 
179 (54) 
452 (137) 
50 
56 (17) 
90 (27) 
143 (43) 
362 (110) 
60 
47 (14) 
75 (22) 
119 (36) 
301 (91) 
70 
40 (12) 
64 (19) 
102 (31) 
258 (78) 
80 
35 (10) 
56 (17) 
89 (27) 
226 (68) 
90 
31 (9) 
50 (15) 
79 (24) 
201 (61) 
100 
28 (8) 
45 (13) 
71 (21) 
181 (55) 
110 
25 (7) 
41 (12) 
65 (19) 
164 (49) 
120 
23 (7) 
37 (11) 
59 (17) 
150 (45) 
130 
21 (6) 
34 (10) 
55 (16) 
139 (42) 
140 
20 (6) 
32 (9) 
51 (15) 
129 (39) 
150 
18 (5) 
30 (9) 
47 (14) 
120 (36) 
160 
17 (5) 
28 (8) 
44 (13) 
113 (34) 
170 
16 (4) 
26 (7) 
42 (12) 
106 (32) 
180 
15 (4) 
25 (7) 
39 (11) 
100 (30) 
190 
14 (4) 
23 (7) 
37 (11) 
95 (28) 
200 
14 (4) 
22 (6) 
35 (10) 
90 (27) 
 
Feet(m) 
mm