3. Technical data:
Size:
80 * 80 * 28 mm
Reading distance:
up to 100 mm (depending on the size of transponder)
Operating temperature:
-10°C to 55°C
Power supply:
through USB
Interfaces:
USB HID / COM
Baud rate (only RS232)
19200
Input / Output (optional):
LCD-Display, Buzzer
Types of transponder:
Hitag2, HitagS, Hitagµ,Q5, EM4305, EM4569
ATA5575 M2, ATA5577, TI HDX+, NCD1015
ATA5575 M2, ATA5577, TI HDX+, NCD1015
4. Buzzer operation (optional extension):
If there is a buzzer present, in mode of operation "MODE 0" the buzzer can be activated for
250ms by sending the "BELL" "07h" character through the interface to the device. When
using a USB-HID device this is only possible at direct communication through the SDK.
250ms by sending the "BELL" "07h" character through the interface to the device. When
using a USB-HID device this is only possible at direct communication through the SDK.
5. LCD-Display (optional extension)
If a LCD-Display (22 x 33mm, 8 x 17 or 4 x 8 characters) is applied, this can be accessed via
the commands from the SDK or directly via the LOW LEVEL commands.
the commands from the SDK or directly via the LOW LEVEL commands.
6. Starting up:
The actual software for these devices is available on our homepage at
http://www.gis-net.de,
in the part RFID-Systeme, menu Software => 134,2 kHz.
As standard application for the devices TS-RW34AC to program and read animal tags the
"GiS TS-W3x-Animal" software is available.
Load the installation file do you need to a folder of your choose. The installation of the
software is started by double clicking the file.
http://www.gis-net.de,
in the part RFID-Systeme, menu Software => 134,2 kHz.
As standard application for the devices TS-RW34AC to program and read animal tags the
"GiS TS-W3x-Animal" software is available.
Load the installation file do you need to a folder of your choose. The installation of the
software is started by double clicking the file.
Hint:
For this device no additional driver from GiS has to be installed!
If the USB HID Interface is used, the standard driver from the windows operating system is
used and this is normally preinstalled.
When using the USB Virtual COM Interface, the device driver from GiS has to be installed.
This driver is installed with all our standard applications or can be loaded separately.
For the Configuration of the Ethernet interface, please see the user’s manual (pdf file) of the
used GiS Software.
For this device no additional driver from GiS has to be installed!
If the USB HID Interface is used, the standard driver from the windows operating system is
used and this is normally preinstalled.
When using the USB Virtual COM Interface, the device driver from GiS has to be installed.
This driver is installed with all our standard applications or can be loaded separately.
For the Configuration of the Ethernet interface, please see the user’s manual (pdf file) of the
used GiS Software.