ELECTRICAL INSTALLATION 
1.2.1.  General 
 
Read the health and safety warnings in section 1.3.  
This unit contains dangerous voltages. Loss of life, severe personal injury, or property damage can be 
the result if the instructions contained in this manual are not followed. 
 
1.  It is compulsory to ground (earth) the unit before connecting the power supply. A grounding bolt is 
provided on the cabinet to connect the ground-bonding cable. 
2.  Although the Remote Unit is internally protected against overvoltage, it is strongly recommended to 
ground (earth) the antenna cables close to the antenna connectors of the Remote Unit for protection 
against atmospheric discharge. In areas with strong lightning, it is strongly recommended to install 
additional lightning protection. 
3.  If the mains connector of the Remote Unit is not easily accessible, a disconnect device in the mains 
power circuit must be provided within easy reach. 
4.  Before  connecting  or  disconnecting  the  mains  connector  at  the  Remote  Unit,  ensure  that  mains 
power supply is disconnected.  
5.  Make  sure  that  an  appropriate  circuit  breaker  acting  as  a  disconnect  device  (as  required  by 
IEC/EN60950-1)  and  an  overcurrent  limiting  device  are  connected  between  mains  power  and  the 
Remote Unit. 
6.  A  connection  of  the  mains  supply  to  a  power  socket  requires  the  power  socket  to  be  nearby  the 
Remote Unit. 
7.  Incorrectly wired connections can destroy electrical and electronic components. 
8.  To avoid corrosion at the connectors caused by electrochemical processes, the material of the cable 
connectors  must  not  cause  a  higher  potential  difference  than  0.6  V  (see  electrochemical  contact 
series). 
9.  Use an appropriate torque wrench for the coupling torque (25 N-m / 19 ft lb) of 7/16-DIN connectors 
with 1 ¼-inch opening to tighten the 7/16-type antenna connectors. For example, use torque wrench 
item  no.  244377  available  from  the  Andrew  e-catalog.  Do  NOT  use  your  hands  or  any  other  tool 
(e.g.  a  pair  of  pliers)!  This  might  cause  damage  to  the  connector  and  lead  to  a  malfunction  of  the 
Remote Unit. 
10. For  unstabilized  electric  networks,  which  frequently  generate  spikes,  the  use  of  a  voltage  limiting 
device is advised.  
11. The unit complies with the surge requirement according to EN 61000-4-5 (fine protection); however, 
installation of an additional medium (via local supply connection) and/or coarse protection (external 
surge protection) is recommended depending on the individual application in order to avoid damage 
caused by overcurrent. 
12. Observe the labels on the front panels before connecting or disconnecting any cables.