Bourgogne ET Grasset SAS VEGRDE2 Manual De Usuario
27-07-2002
Vegas Long Range Read/Write Device
Page 19 (48)
Confidentiality Level 1
Vegrde3/EG
Bourgogne et Grasset -– ZI Beaune Savigny -– 21200 Beaune – France – Tel. +33 380 26 26 26 – Fax. +33 3 80 26 26 00
3.3.10. MutualAuthent
Carries out the full authentication procedure of the data carrier and the read/write device.
After this mutual authentication you are allowed to edit areas which can only be accessed in
SECRET Mode.
Use a Plain command (that is encrypted), ResetHFSystem or GetSnr to exit this mode.
Using -loginfo- you can choose between Log information (Keys and Logdata) A and B.
Definition:
void proloc_MutualAuthent (BYTE loginfo);
Serial protocol:
HOST - Read/Write Device
0x03 'A' loginfo BCC
Read/Write Device - HOST
0x02 Status BCC
loginfo:
0 ...
loginfo A
1
...
loginfo
B
Status:
0 ... no error
- 1 ...
SERIAL error
- 7 ...
AUTHENT error
3.3.11. ReadAllPage
Reads all Pages of Data Carriers in the active antenna field.
Definition: void proloc_ReadAllPage (BYTE pagenr, BYTE mode, BYTE *data, BYTE
*datalen);
*datalen);
Serial protocol:
HOST - CORE MODULE
HOST - CORE MODULE
0x04 0x98 mode pagenr BCC
mode: Bit 0: 0=use KEY0 for Authentification
1=use KEY1 for Authentification
Bit 1: 0=Plain
(without Authentification)
1=Crypto
(with
Authentification)
CORE MODULE - HOST
n+2 Status
Data[0] ....... Data[3] BCC