Bourgogne et Grasset  -– ZI Beaune Savigny  -– 21200 Beaune  –  France  –  Tel. +33 380 26 26 26  –  Fax. +33 3 80 26 26 00 
 
5.3.3. OTP-Byte 1 
 
 
 
As soon as the OEM Lock Bit is set to 0 the configuration page cannot be 
changed any more! 
 
*) Changing this bit the data carrier cannot be operated any more! 
 
5.3.4. Default Configuration of HITAG VEGAS Data Carriers 
HITAG VEGAS data carriers are delivered with the following configuration by Mikron: 
 
Serial Number: 
Read Only 
fixed 
Key A, Key B: 
Write Only 
can be changed 
Logdata: 
Read/Write 
can be changed 
OTP Page: 
Read/Write 
can be changed 
Blocks 2 - 7: 
Read/Write 
can be changed 
Blocks 4 - 7: 
Public Access 
can be changed 
 
According to that the OTP bytes display the pattern illustrated below: 
 
OTP Byte 0   
Bit 
7       Bit 
0
1 1 1 1 1 1 1 1 
OTP Byte 1   
Bit 
7       Bit 
0
1 1 0 1 1 1 
 
You cannot change Bits 5, 6, and 7 of OTP Byte 1 (gray background). If you attempt to write the 
configuration page with a bitmap that changes one of these three bits, the Write command will 
be executed without displaying an error message but the memory contents of OTP 1/Bit 5, OTP 
1/Bit 6, OTP 1/Bit 7 will remain unchanged.