1.  GENERAL INFORMATION 
 
 
Congratulations on purchasing one of the finest HF amplifiers in the world today.  Acom is pleased that you 
have chosen one of our products, and we will endeavor to provide you with the information and support you 
need to enjoy your purchase for many years.  We urge you to read all of the following materials before you 
embark on operating your new amplifier. 
1-1. Introduction and Description 
 
This manual explains the installation, operation, and maintenance of the ACOM1010 HF linear amplifier. 
The ACOM1010 is a self-contained linear amplifier that covers all amateur bands, from 1.8 through 29.7 
MHz.  It provides over 700-W PEP of output power (or 500 W in continuous-duty operation) with less than 
60-W of drive.  The amplifier is designed to tolerate VSWR levels of up to 3:1 throughout its operating 
range, and tuning is simplified by Acom’s exclusive True Resistance Indicator (TRI).  Also, a built-in antenna 
selector switch with two outputs is included to provide instant choice of antennas.  Importantly, a variety of 
system parameters are continuously monitored and available to the operator to assure safe and efficient 
amplifier operation. 
1-2. Owner Assistance 
If technical or operating assistance is needed, your local dealer should be contacted first. In the unlikely 
event you need further information, you may get in touch with Acom by facsimile, telephone, email or 
standard mail.  Fax: + 359 2 920 9656; telephone: + 359 2 920 9655; e-mail: 
acom@mail.orbitel.bg;
 
standard mail:  Acom bul. N.Mushanov Nr.151, 1330 Sofia, Bulgaria. 
1-3. Equipment Supplied 
The ACOM1010 amplifier and this manual are shipped in a cardboard carton. 
1-4. Features 
• Easy 
operation. The plate-load True Resistance Indicator (TRI) is an ACOM innovation that provides 
quick and precise tuning, typically in less than 10 seconds.  The auto-operate function will return the 
amplifier to the OPERATE mode automatically after each protection trip, saving time and avoiding manual 
switching. 
•  No tuner needed.  No external antenna tuner is required as long as the antenna VSWR is 3:1 or lower. 
The amplifier will perform the functions of an antenna tuner, enabling you to change antennas faster and 
use them over wide frequency ranges. 
• A 
durable 
amplifier.  This amplifier is both user-friendly and self-monitoring.  It is designed to safely 
withstand up to 240 W of reflected power, up to 100 milliseconds of drive spikes (RF "tails" after a PTT or 
KEY release), and even operator tuning errors.  It is also capable of operating at more than half its designed 
output power at only 75% of nominal line (mains) voltage.  Because it can tolerate deep voltage drops 
(down to zero for 10 milliseconds) and 15% line voltage spikes,  it is particularly suited for use in portable 
environments, such as field days and DXpeditions.  
• LED 
bar-graph 
display. The upper LED bar-graph always reads peak forward power while the lower 
LED bar-graph is for the reflected power. LED warning indicators are provided for abnormal conditions of 
grid 1, grid 2, and plate parameters.   
• Antenna 
selection.  Two antenna outputs are selectable on the front panel of the amplifier. 
• Efficient 
tuning.  Antenna matching can be achieved in less than 10 seconds and at a quarter of nominal 
output power, which produces lower risk of interference to other stations and greater safety to the amplifier 
components. 
• Transceiver-independent.  The amplifier operates without special signaling from the transceiver; it 
needs only "ground on TX" and 60 W RF drive power to operate at full output power. 
• Input 
matching.  Broadband input matching circuitry offers excellent loading characteristics for the 
driving transceiver, from 1.8MHz to 30MHz. 
•  Single tube operation.  A single Svetlana 4CX800A (GU74B) high-performance ceramic-metal tetrode 
with plate dissipation of 800W (forced air cooling, grid-driven) is used for maximum efficiency. 
•  Permanent monitoring and protection of the plate and grids currents. The Bias Optimizer minimizes heat 
dissipated by the tube, assuring tube longevity.