  Configuring Field Units and Repeaters 
All field units and repeater units have various configurable parameters. When registering a unit with the 
concentrator, the unit receives its default setting definitions from those defined for the concentrator. 
You can redefine the concentrator settings before registration to automatically upload the modified 
settings to the units upon registration. In addition, after registration, you can modify the settings for any 
unit 
individually
The configuration options for the concentrator, all field units, and all repeaters are as follows: 
 
Sampling Period – Frequency with which the Radio INT adaptor card samples the field unit. 
Default value: 1 second. 
 
Reporting Period – Frequency with which a field unit sends status reports to the concentrator. 
Default value: 1 minute. 
 
Charge Time
 
– Maximum waiting time to charge the capacitor before operating the valve. 
Default value: 30 seconds. 
 
Output setting
 
– Not relevant. Default value: ALL OFF. 
 
Digital Input 0 -7 – For each input, you can define the number of pulses, with which a field unit sends 
status reports to the concentrator. Default value: 1 pulse.
 
Modifying the Default Field Unit Configuration Settings in the 
Concentrator 
To change the default field unit configuration settings in the concentrator: 
1.  Press 
 until “INSTALLER MENU” is displayed on the screen, and press 
 to select it. 
2.  Enter technician code 9999. The concentrator emits four beeps and requests confirmation. Do not 
change the technician code. 
3.  Press 
 until “DEVICES” is displayed on the screen, and press 
 to select it. 
4.  Press 
 until “DEFINE DEFAULTS” is displayed on the screen, and press 
 to select it. 
5.  Press 
 to browse through the list of configuration parameters. When the parameter you want to 
modify is displayed, press 
6.  Press 
 to browse through the various settings options for the selected parameter and click 
 
when the desired value is displayed. The concentrator emits four beeps and displays the message 
SAVING while saving the modified parameter setting. 
After saving the modifications, the screen returns to the selected parameter. 
7.  Optionally, browse to other configuration parameters and modify them as desired.