EnOcean GmbH STM300C Manual De Usuario

Descargar
Página de 46
USER MANUAL V0.82 
© 2010 EnOcean  |  www.enocean.com 
TCM 300 / 300C / 320 / 320C User Manual V0.82  |  Page 29/43 
 
 
TCM 300 / 300C / 320 / 320C 
3.7  Soldering information  
3.7.1  TCM 300 / TCM 300C 
 
TCM 300 has to be soldered according to IPC/JEDEC J-STD-020C standard. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
TCM 300 shall be handled according to Moisture Sensitivity Level MSL4 which means a floor 
time of 72 h. TCM 300 may be soldered only once, since one time is already consumed at 
production of the module itself. 
 
Once the dry pack bag is opened, the desired quantity of units should be removed and the 
bag resealed within two hours. If the bag is left open longer than 30 minutes the desiccant 
should be replaced with dry desiccant. If devices have exceeded the specified floor life time 
of 72 h, they may be baked according IPC/JEDEC J-STD-033B. 
Devices packaged in moisture-proof packaging should be stored in ambient conditions not 
exceeding temperatures of 40 °C or humidity levels of 90% r.H. 
 
TCM 300 modules have to be soldered within 6 months after delivery!