Crane Electronics Ltd PO Manual De Usuario

Descargar
Página de 31
30
ProWrench Opta
GLOSSARY OF TERMS
Batch
A group of readings taken. ProWrench Opta stores these readings by default
in the Quick Store mode.
Configure
The process of entering and storing the basic parameters which determine the
resulting outputs of ProWrench Opta.
Cycle End Time
Is the time the torque must be below threshold for the reading to finish.
Direction of Rotation
The direction in which the wrench is turned to apply torque - Clockwise (right)
or Anticlockwise (left).
Job
A series of torque applications to be measured together.
Peak
A type of measurement which records the highest torque applied to a trans-
ducer during an operation.
Round
A series of Jobs to be performed together.
Sample
Individual torque reading.
Span
The Span is the effective operating range of the wrench. This is the range
between zero and the maximum design limit of the transducer.
Threshold Torque Value
The level of torque which a signal must rise above and then fall below to be
considered a valid torque cycle. In the ProWrench II, this is set at 5% of the
rated span of the transducer.
Target
The target torque figure.