Gasngo R&D Ltd. RDR008 Manual De Usuario
33
Chapter 3 – Station Installation Manual
Figure 12: Opening the Connector
Gently lift up the locking mechanism and pull the two parts of the connector in opposite
directions.
Do not pull from the connector from the cable.
Black (Old) connector
Connect the battery to the Reader.
Before connecting the battery to the Reader, verify the position of the connector pins.
(See arrows in Figure 12)
A wrong connection (as shown by the arrows above) can cause a short circuit and
destroy the battery!
destroy the battery!
Figure 13: Battery Connector polarity check
Installing the Reader in the insulator
1. Set the wire around the back part of the Reader and fix it with 3 plastic strips.
Make sure to do this clockwise.