Gasngo R&D Ltd. RDR008 Manual De Usuario

Descargar
Página de 66
 
 
59
Chapter 3 – Station Installation Manual         
 
 
Appendix 4 - eGSC Installation 
 
Overview 
The eGSC (embedded eGSC) is used when the station PC is not available or the device has to be 
installed on a track. 
The eGSC enclosure is same as the GSC. 
 
Please consult Gasngo Technical team before ordering or installing the eGSC. 
 
eGSC contents 
The eGSC (embedded GSC) contained the following parts: 
1.  GSC 
2.  Embedded Windows XP board 
3.  AVI Service software 
4.  TCOM software for communicating with external components at the station 
Remote shutdown and restart of eGSC 
Turning the eGSC off without proper shutdown procedure might jeopardize system 
performance. Avoid powering of the eGSC without proper shutdown. 
 
In order to restart or shutdown the eGSC please follow these instructions: 
1.  Use a remote PC that can be connected to the same LAN as the eGSC 
2.  Select Start -> Run 
3.  Enter “cmd” 
4.  The command line window will open. 
5.  Enter: 
telnet <eGSC IP> 5555 
For example, in case of an eGSC board with the IP Address 192.168.0.171, enter: 
telnet 192.168.0.171 5555 
6.  The window shown in Figure 35 will open.