Page 39 
ALIGNMENT & TESTING 
6.1.2 
Sending Configuration Information 
Firstly,  the  configuration  file  for  the  radio  needs  to  be  setup.    Using  MxTools  the  configuration 
information needs to be entered on the Configuration Screen.  This information needs to be saved 
to  a  configuration  file.    If  an  existing  radio  already  contains  the  desired  configuration,  this 
configuration can be downloaded and saved.  This configuration information then needs to be ‘Sent 
to the SB2025’.  A warning message will appear that indicates that the SB2025 Base Station has 
not yet been calibrated, this may be ignored. 
Once the configuration information has been sent, all of the programmable parameters within the 
SB2025 Base Station are initialised. 
6.1.3 
Sending Channel Information 
The channel information setup is similar to that of the configuration.  The channel frequencies, sub-
tones and other parameters are setup in the Channel Screen in MxTools.  At this stage, it is not 
necessary  to  set  the  values  of  the  digital  potentiometers.    This  will  be  done  in  the  following 
procedures.  After  entering  in the  channel  details, the  information  needs  to  be  saved  to  a file.   If 
another radio already contains the desired frequencies, these can be downloaded from that radio 
and saved to a file.  The digital potentiometer values from one radio to the next will differ, therefore, 
it is advisable to save the information in a new channel file and not save over the top of any backup 
copies of existing radios.  The saved channel information is then sent to the SB2025NT. 
After  sending  the  configuration  and  channel  information,  the  SB2025NT  is  fully  programmed  and 
will  now  operate.   The  radio  will  not  function without  sending  both  the  configuration  and  channel 
information and, therefore, the following procedures will be unable to be completed. 
Note. 
The  buttons  for  sending  and  loading  the  channel  information  may  be  disabled  if 
MxTools did not successfully ‘Connect to SB2025’.  If this is the case, simply choose 
to ‘Connect to the Radio’ after the configuration information is sent. 
6.1.4 
Setting Alignment Channel 
When setting up the radio, it is recommended that all measurements and adjustments are done on 
a channel that is in the centre of the frequency spread of the channels.  This minimises any errors 
due to frequency changing.  Alternatively, if the frequency spread of the channels is too large, you 
may wish to calibrate and align every channel.  (In most cases this will not be necessary.)  Both 
individual and group alignment will be covered. 
The channel may be selected either via the Channel Screen in MxTools using the software channel 
select or in hardware via the internal channel DIP switch.  (Refer to Section 3.2.2.3 for additional 
help.)  This channel will then be used when performing the following procedures. 
6.1.5 
Power Calibration 
This procedure must NOT be used to set the Tx Output Power.  For the Tx Power 
Adjustment procedure, refer to Section 6.1.8. 
Power  calibration  affects  the  forward  and  reflected  power  meters  on  the  Diagnostics  Screen,  as 
well as the low forward power trip point for the SB2025NT.  This procedure requires a RF Power 
Meter  and  the  relevant  leads  to  connect  the  Tx  output  to  the  meter.    Power  calibration  is  done 
using MxTools via the Calibration Screen. 
To complete the power calibration, carry out the following: 
1. 
On  the  MxTools main  screen,  on  the  tool  bar,  select  the  ‘Calibration’  icon.    The  calibration 
screen will be displayed.