Simoco EMEA Ltd SB2K5354O2O2V Manual De Usuario

Descargar
Página de 202
 
SGD-SB2025NT-TUM, Part 1 
Jan 12 
Page 76 
APPENDIX C 
APPENDIX D 
SB2025 MICRO CONTROLLER PCB LINK SETTINGS 
The  link  settings  detailed  in  this  Appendix  should  only  be  carried  out  by  qualified  engineering 
personnel. 
 
CAUTION 
Electrostatic Discharge Sensitive Devices (ESDS Devices).  This equipment 
contains ESDS Devices, refer to the Personal Safety and Equipment Safety 
pages. 
 
L
INK 
S
ETTINGS
 
For correct operation of the Solar 2 P25 NI in the SB2025 base stations, two separate audio paths 
for  the  Tx  Audio  and  Rx  Audio  have  to  be  created  through  the  Micro  Controller  PCB.    This  is 
achieved by adjusting various link and jumper settings on the Micro Controller as detailed below. 
For  details  of  the  Micro  Controller  PCB  component  layout,  refer  to  Section  8  –  Drawings.    The 
location of the links and jumpers detailed below are shown overleaf in Figure D-1
For details of the functions of the Micro Controller Jumpers, refer to Section 3 – Installation and 
Operation
Tx Audio 
This input from Solar 2 NI enters the SB2025 on Pin 13 of CN1 DB15 Line I/O connector. 
• 
JMP8 
2-3 
IN. 
• 
JMP27  2-3 
IN. 
• 
T99 link  
IN. 
Rx Audio 
This output to Solar 2 NI leaves the SB2025 on Pin 14 of CN1 DB15 Line I/O connector. 
• 
SKK 
1-2 
OUT