SDB670 – SERVICE MANUAL 
TNM-M-E-0032 
May 13 
Page 45 
MAINTENANCE 
4. 
The Rx Assembly can now be removed from the unit. 
Figure 12.  Removal of Rx Assembly. 
6.2.5 
To Remove the Control Board 
1. 
Remove the lid and open the SDB670 as detailed in Section 5.2.2
 
CAUTION 
This equipment contains ESDS Devices, static handling procedures are to be 
observed.  Refer to the personal safety pages. 
 
2. 
On the Control Board, referring to Figure 13 overleaf, carry out the following: 
2.1.  Disconnect the fan power cable from connector ‘P8FAN’. 
2.2.  Disconnect the DC power cable from connector ‘VDC’. 
2.3.  Disconnect the Tx, Rx and MMI RJ45 cables from the RJ45 sockets ‘TX’, ‘RX1’ and ‘S3 
MMI’ respectively. 
3. 
On  the  SDB670  rear  panel,  remove  the  four  socket  fasteners  from  the  9-way  and  25-way 
connectors. 
4. 
On the Control Board, release the six screws that secure the Control Board to the mounting 
pillars. 
5. 
Carefully lift out the Control Board from the unit. 
Rx RF Cable
(BNC)
Rx Engine to
Control Board Cable
(RJ45)
Power Cable
(from socket S2
on Fuse Board)
M
4
 N
u
ts
 s
e
c
u
ri
n
g
R
x
 A
ss
e
m
b
ly