Simoco EMEA Ltd SDB670AC01 Manual De Usuario

Descargar
Página de 56
SDB670 – SERVICE MANUAL 
TNM-M-E-0032 
May 13 
Page 49 
MAINTENANCE 
2.3.  The Control Board power cable to connector ‘S4’. 
2.4.  The DC power in and Battery Back-up out cable to connector ‘S5’. 
3. 
On  the  PSU,  connect  the  power  cables  to  the  screw  connections  of  ‘TB1’  as  detailed  in 
Table 15 below. 
Table 15.  PSU TB1 Connections. 
TB1 
Terminal 
Cable Colour 
Details 
+V 
Red 
+ve DC Output to S5 (VIN pin) connector on Fuse Board. 
-V 
Black 
-ve DC Output to S5 (top 0V pin) connector on Fuse Board. 
Green/Yellow 
Earth connection to SDB670 chassis. 
FG 
Green/Yellow 
Earth wire 
Brown 
Live wire 
Blue 
Neutral wire 
AC mains Input from rear panel. 
 
6.3.5 
To Fit the Control Board 
 
CAUTION 
This equipment contains ESDS Devices, static handling procedures are to be 
observed.  Refer to the personal safety pages. 
 
1. 
Carefully place the Control Board into the SDB670 chassis, ensuring that all the connectors 
are correctly located in their respective cut-outs on the rear panel and that the Control Board 
is correctly located on the six PCB mounting pillars. 
2. 
Once in position, secure the Control Board into position on the six PCB mounting pillars with 
the six screws provided. 
3. 
On the SDB670 rear panel, secure the control boards’ 9-way and 25-way connectors to the 
chassis with the four socket fasteners. 
4. 
On the Control Board, carry out the following: 
4.1.  Connect the fan power cable to connector ‘P8FAN’. 
4.2.  Connect the Control Board DC power cable to connector ‘UDC’. 
4.3.  Connect the Tx, Rx and MMI RJ45 cables to the ‘TX’, ‘RX1’ and ‘S3 MMI’ RJ45 sockets 
respectively. 
6.3.6 
To Fit the Rx Assembly 
1. 
Taking care not to trap any cables, position the Rx Assembly onto the four M4 locating studs 
on the SDB670 chassis.  Secure in place with the four M4 hexagonal nuts. 
2. 
On the Rx Assembly, referring to Figure 12, carry out the following: 
2.1.  Connect the Rx RF cable to the BNC socket. 
2.2.  Connect the Rx Engine to Control Board cable to the RJ45 socket.