7.7.2 ADDING RFPS FOR CONFIGURATION
Before you can configure an RFP, you must add the RFP to the OM Configurator database. You can add
an RFP record by:
an RFP record by:
•
scanning for RFPs that are already attached to the network
•
entering the MAC address of the RFP
•
loading a configuration file that contains RFP MAC addresses and configuration parameters
Please note:
Adding an RFP to the OM Configurator database does not modify the RFP
configuration. Configuration data must be transmitted explicitly to the RFP(s) through the
Send Configuration option.
Send Configuration option.
7.7.3 SCANNING FOR RFPS
The OM Configurator tool can scan for RFPs on the LAN segment.
•
If
get configuration after detecting an RFP is enabled, the OM Configurator attempts to fetch the
local configuration settings from all RFPs that are detected during the scan. The program uses the
user/password combination if an access without login data fails.
user/password combination if an access without login data fails.
•
If
show only successfully accessed RFPs is enabled, the OM Configurator adds only RFPs that
provide configuration information to its database, and displays those RFPs in the OM Configurator
table.
table.
•
The
use Proxy parameter allows access to RFPs that are located in network segments other than
the segment that hosts the OM Configurator. The
IP-address field must contain the address of a RFP
located in the network segment to be scanned. This RFP works as proxy and must be up and running.
You initiate the scan process by clicking
OK button. The OM Configurator adds the results to the table.
In rare cases, it is possible that a RFP is expected to appear in the table after the scan operation but
does not. If this occurs, repeat the scan operation.