Geonautics International Pte Ltd 30-0710 Manual De Usuario

Descargar
Página de 53
TAG-T3 Wombat – User Guide, 1.0.7  
Commands
 
 
4.6.2  Region (GeoFence) 
 
As the 
TAG-T3 moves in or out of the area, the unit will fire the 
External Trigger Relay. 
 
 
$GO0,,RG1[,<North>][,<South>][,<East>][,<West>] 
[,<Relay ON|OFF,][,<Name>] 
 
 
$GOA,<Unit_Id>,RG1,<North>,<South>,<East>,<West>, 
<Relay ON|OFF>,<Name> 
 
 
Region (Alarm)
 
Description 
North 
The northern limit of the region (latitude in degrees) 
South 
The southern limit of the region (latitude in degrees) 
East 
The eastern limit of the region (longitude in degrees) 
West 
The western limit of the region (longitude in degrees) 
Relay  
Fire relay when inside region, OFF to disable, see 
Name 
Name of Region Alarm 
Table 13, Region (Alarm) Command 
 
 
Default: $GO0,,RG1,0.0,0.0,0.0,0.0,OFF,ONE 
 
Example:  $GO0,,RG1,-27.5,-27.6,153.2,153.1,ON,BOX_1 
 
Returns:
 
$GOA,<Unit_Id>,RG1,27.5,27.6,153.2,15
3.1,ON,BOX_1 
 
 
 
 
Note:  When the alarm is triggered and relay is set, the unit will fire 
the external Relay Trigger. 
 
© Geonautics 
33 
Law Enforcement ONLY