Geonautics International Pte Ltd 30-0710 Manual De Usuario
TAG-T3 Wombat – User Guide, 1.0.7
Commands
4.9.3 Debug (Live)
Turn on and off the debugging information.
$GO0,,DBG[,ON|OFF]
$GOA,<Unit_Id>,DBG,ON|OFF
When ON, the following debug information is output every second.
$GOM,<Unit_Id>,DBG,<ModulesStatus>,<LocalTime>,,<TRXTime
r>
,<GPSTimer>,<BackdoorTimer>,<SpaceVehicles>,<Logs>,<Voltag
e>
,<Current>,<Temperature>,<MotionStatus>,<MotionTimer
$GO0,,DBG[,ON|OFF]
$GOA,<Unit_Id>,DBG,ON|OFF
When ON, the following debug information is output every second.
$GOM,<Unit_Id>,DBG,<ModulesStatus>,<LocalTime>,,<TRXTime
r>
,<GPSTimer>,<BackdoorTimer>,<SpaceVehicles>,<Logs>,<Voltag
e>
,<Current>,<Temperature>,<MotionStatus>,<MotionTimer
>
Debug String
Description
-|B
if TRX is currently ON due to the backdoor interval,
otherwise -
otherwise -
-|T
if TRX is currently ON, otherwise -
Module
Status
Status
-|G
if GPS is currently ON, otherwise -
Local Time
Local Time of unit, represented as hh:mm:ss
TRX Timer
Counts down to zero when TRX ready to turn ON,
otherwise up ‘til the TRX has completed its interval
otherwise up ‘til the TRX has completed its interval
GPS Timer
Counts down to zero when GPS ready to turn ON,
otherwise up ‘til the GPS has completed its interval
otherwise up ‘til the GPS has completed its interval
Backdoor Timer
Up to 120 when backdoor ON, otherwise shows the
time ‘til midnight
Space Vehicles
Satellites used in the current GPS solution fix
Logs
Number of logged positions currently stored on device
Voltage
Input Voltage on device
Current
Current being used by device, expressed as mA
Temperature
Temperature of device in degrees C, low accuracy
Motion Status
Status of the motion sensing
S: Stationary
s:
Stationary but yet to complete final log
M: Movement
sensor
T: External
trigger
v: Under
voltage
V: Over
voltage
Motion Timer
Counts down to the completion of the motion
Table 23, Debug String