9.3 Write Memory Card
To write data to the specified address of the inserted card. The byte is written to the card with LSB
first, i.e., the bit at card address 0 is regarded as the LSB of byte 0.
first, i.e., the bit at card address 0 is regarded as the LSB of byte 0.
The byte at the specified card address is not erased prior to the write operation and, hence, memory
bits can only be programmed from '1' to '0'.
bits can only be programmed from '1' to '0'.
• Command format
Pseudo-APDU
CLA
INS
P1
Byte
Address
MEM_L
Byte 1
....
....
Byte N
FF
H
D0
H
00
H
Byte Address
= Memory address location of the memory card.
MEM_L
Length of data to be written to the memory card.
BYTE
Byte value to be written to the card
• Response data format
SW1
SW2
• SW1, SW2
= 90 00 if no error
9.4 Erase Non-Application Zone
To erase the data in Non-Application Zones. The EEPROM memory is organized into 16 bit
words. Although erases are performed on single bits the ERASE operation clears an entire word in
the memory. Therefore, performing an Erase on any bit in the word will clear All 16 bits of that
word to the state of ‘1’.
words. Although erases are performed on single bits the ERASE operation clears an entire word in
the memory. Therefore, performing an Erase on any bit in the word will clear All 16 bits of that
word to the state of ‘1’.
To erase Error Counter or the data in Application Zones, please refer to:
- Erase Application Zone With Erase command as specified
- Erase Application Zone With Write and Erase command as specified
- Verify Security Code commands as specified
- Erase Application Zone With Write and Erase command as specified
- Verify Security Code commands as specified
• Command format
Pseudo-APDU
CLA
INS
P1
Byte
Address
MEM_L
FF
H
D2
H
00
H
00
H
Byte Address
= Memory byte address location of the word to be erased
.
• Response data format