Culligan International Company 01020553 Manual De Usuario
Follow the procedure below to initiate a manual regeneration at the control valve or the remote display.
system ok
12:00 am 1-1-08
1) information
> 2) manual mode
3) set date/time
4) Accessories
Press DOWN arrow. Scroll to MANUAL MODE.
Press the CHECK MARK button to select.
The “REGEN OFF” value is the default setting.
Press the CHECK MARK button to change manual mode setting. Use the UP or DOWN arrow to change the set-
ting. Once the desired value is displayed, this value can be accepted by pressing the “CHECK MARK” button.
By selecting the “REGEN TONITE” value the softener will regenerate that night at 2:00
AM (or at the preset regeneration time)
By selecting the “REGEN NOW” value the softener will begin regeneration immediately.
NOTE: In multi-tank systems, the regeration request is sent to the master control and it
will allow the unit to regerate at the next availble time.
Press the “CANCEL” button to return to the “home” screen.
Manual Mode
>Regen off
Manual Mode
Regen tonite
Manual Mode
Regen now
Manual Regeneration
Manual Cycling
50
49
CULLIGAN GLOBAL ELECTRONIC CONTROLLER