SBT AVG T3: In addition to these four sensors, the SBT probe takes a measurement 
during each regeneration cycle called “T3”. This measurement varies from system to 
system, but is typically between 10 and 60 seconds for a system. When the SBT is 
turned from UNINSTALLED to INSTALLED on the Accessories menu, the average value 
of T3 is erased and the system will use the next three regeneration cycles to compute 
a new T3 average number.  During each subsequent regeneration, the new T3 is compared to the average T3 
number. If the new T3 exceeds the average T3 by more than 50% then the system will display a “Brine Line 
Blockage – Check Brine Line” error message. The average T3 value is displayed on the diagnostic screen after the 
SBT sensor screen.
Press DOWN arrow to view the next statistic.
SBT LAST T3: Smart Brine Tank Probe troubleshooting statistics. This is the last T3 valve 
recorded by the probe. Press DOWN arrow to view the next statistic.
Test Wireless: See page 37.
Test Progressive Flow:
Scroll to ADVANCED SETUP and select
Scroll to DIAGNOSTICS and select
Scroll to TEST PROGRESSIVE FLOW and Select
The progressive test screen will show the data packet transmissions from the Master (Tx) 
and which slaves are recieving (1,2,3,4 and/or 5). For example, in a triple system, if 
the transmission from the master (Tx) is 0085, then you should see 1:0085 and 2:0085. 
3,4, and 5 will remain all zeros since no other slaves are connected.
See page 50
See Appendix C, page 65
See page 40
IGNORE THIS
sbt last t3
30 seconds
sbt avg t3
30 seconds
Diagnostics
 
Menu Lockout and Menu Default 
58
57
  CULLIGAN GLOBAL ELECTRONIC CONTROLLER
 > 5) advanced setup
 > 5) Diagnostics
system ok
7:32 am 2-1-08
 > 4) Test Progressive Flow
  Progressive Test
  1:0000, 2:0000
  3:0000,  4:0000
  5:0000, Tx: 0000
 Use Data Port
 Test phone line
  Motor Control
 Test wc app