Brivo ACS300 Installation Manual 
Page 12 
 
 
 
 
© 2017 Brivo Systems LLC. All rights reserved. 
Rev 1
 
 
The ACS300 Tamper On/Off Toggle in the off position deactivates both optical 
and physical tamper switches. 
 
 
Tamper Switch and Optical Tamper Sensor Locations 
If there is no reflector present, the optical tamper will not activate. The presence of the optical reflector is 
required for this functionality. 
OPTIONAL: Connect the physical tamper switch to the ACS300. 
If the ACS300 unit is installed within an external metal chassis (i.e., ACS6000-EXP), the option for 
attaching an external physical tamper switch is provided. 
Connect the physical tamper switch to the ACS300. 
 
Connect Tamper Switch to the ACS300 
b)  The tamper header connects to the supplied tamper switch. 
c)  The header connector for the tamper switch should be connected to the 
TAMPER pins located on the upper right side of the ACS300.  
 
 
NOTE: If the tamper switch is not going to be used, leave the supplied 
jumper on this connector to keep the circuit closed.