Display Battery
If the digits on the Display are faded, and you cannot establish a connection to the 
Armband, then the battery may require replacing.  The Display comes equipped 
with a replaceable CR-2032 coin cell battery with an expected life of 6-12 months 
under normal use.  When the battery needs to be replaced, it is recommended that 
you bring the Display to a jeweler or watch vendor. To replace the battery yourself:
1. Make sure you have a fresh CR-2032 coin cell battery, a #0 size Phillips head   
    screwdriver, and a soft cloth. 
2. Remove the Display unit from the clip.
3. Turn the unit over onto a soft cloth, revealing the underside, and remove the four 
    small screws attaching the metal back plate to the Display.  Only remove the  
    screws on the metal back plate, do not remove the screws on the edge of the 
    Display.
4. Remove the old battery.
5. Press any button on the display for 10 seconds.
6. Place the new battery with the (+) side facing up.
7. Ensure that the black o-ring gasket remains properly seated in the groove to 
    provide a watertight seal. 
8. Reattach the back plate, with the text facing up.  Ensure that the arrow that says  
    up (on the inside of the metal back) points towards the top of the device. 
9. Once attached, turn the unit over and press any button to wake the Display.
10. Dispose of the old battery in accordance with local, state, federal, or country 
    specific regulations.
Note:  Once the battery is replaced, you will need to reset the Display.  Simultane-
ously press all 4 buttons, “MODE” + “VIEW” + “LIGHT” + “RESET TRIP” for 5 
seconds or more.  The Display will turn on and the back-light will flash. 
The Display will turn on and the back-light will flash. Follow the instructions for 
“Using the Display” on page
 
8 to synchronize again with the Armband.
Energy Information (calories)
Energy information on the Display is reported in kcal.  You may convert between 
kcal and kJ as follows.  1 kcal equals 4.2 kJ. For example:
The Armband is not designed to be used underwater or to come into continuous 
contact with water.  Do not immerse the Armband in water. 
 
The Display is water resistant up to 30 meters.
To ensure the Armband and Display are working correctly, they should be cleaned 
regularly.
Clean the Armband and Display daily after sweating or when either one becomes 
noticeably moist or dirty.  Failure to keep the Armband and Display clean, or 
improper cleaning, may irritate the skin and affect the sensor performance.  Do not 
13
Water Resistance
Care Instructions
kJ
837
2,092
8,368
10,460
kcal
 
200
500
2,000
2,500