BodyMedia Inc. 185 Manual De Usuario
BodyMedia FIT Armband BW Manual
BodyMedia FIT Armband BW Manual
Flicker
IEC 6100-3-3
IEC 6100-3-3
N/A
Harmonics
IEC 6100-3-2
IEC 6100-3-2
N/A
The Armband is suitable for use in all establishments,
including domestic, and those directly connected to the
public low-voltage power supply network that supplies
buildings used for domestic purposes.
including domestic, and those directly connected to the
public low-voltage power supply network that supplies
buildings used for domestic purposes.
RF Emissions
CISPR 11
CISPR 11
Class B, Group 1
The Armband uses RF energy only for its internal func-
tion. Therefore, its RF emissions are very low and are
not likely to cause any interference in nearby electronic
equipment.
tion. Therefore, its RF emissions are very low and are
not likely to cause any interference in nearby electronic
equipment.
The Armband is intended for use in the electromagnetic environment specified
below. The customer or user of the Armband should ensure that it is used in such
an environment.
Guidance and Manufacturer’s Declaration - Emissions
Emissions Test
Compliance
Electromagnetic Environment - Guidance
Computer and Wireless Communicator
1.5m
Diagram not to scale.
1.5m
1.5m
2.5m
User Environment
20
Power frequency magnetic fields should
be that of a typical commercial or hospital
environment.
be that of a typical commercial or hospital
environment.
Mains power quality should be that of a
typical commercial or hospital
environment. If the user of the Armband
requires continued operation during power
mains interruptions, it is recommended that
Armband be powered from an uninterrupt-
ible power supply or battery.
typical commercial or hospital
environment. If the user of the Armband
requires continued operation during power
mains interruptions, it is recommended that
Armband be powered from an uninterrupt-
ible power supply or battery.
Mains power quality should be that of a typi-
cal commercial or hospital environment.
cal commercial or hospital environment.
Floors should be wood, concrete, or ceramic
tile. If floors are synthetic, the r/h should be
at least 30%.
tile. If floors are synthetic, the r/h should be
at least 30%.
Electromagnetic
Environment - Guidance
3A/m
Power
Frequency
50/60Hz
Frequency
50/60Hz
Magnetic Field
IEC 61000-4-8
IEC 61000-4-8
3A/m
N/A
Voltage Dips/
Dropout
IEC 61000-4-11
Dropout
IEC 61000-4-11
>95% Dip for
0.5 Cycles
60% Dip for 5 Cycles
30% Dip for 25
Cycles
>95% Dip for 5
Seconds
0.5 Cycles
60% Dip for 5 Cycles
30% Dip for 25
Cycles
>95% Dip for 5
Seconds
N/A
s
±1kV Differential
±2kV Common
±2kV Common
N/A
EFT
IEC 61000-4-4
IEC 61000-4-4
±2kV Mains
±1kV I/Os
±1kV I/Os
The Armband is intended for use in the electromagnetic environment specified
below. The customer or user of the Armband should ensure that it is used in such an
environment.
Guidance and Manufacturer’s Declaration - Immunity
±6kV Contact
±8kV Air
±8kV Air
ESD
IEC 61000-4-2
IEC 61000-4-2
±6kV Contact
±8kV Air
±8kV Air
Immunity Test
IEC 60601
Test Level
Compliance
Level
21