Comba Telecom Ltd. RX4122-B Manual De Usuario

Descargar
Página de 54
INSTALLATION GUIDE FOR RX-4122 
 
ENU STATUS : 1-0-1 
Copyright - refer to title page 
Page 43 
 
 
 
 
 
Figure 38: Channel parameters setting-Class A 
 
Reminder:  
 
 
Make sure the frequency of sub-bands match the actual frequency of filters, or BDA cannot work normally. 
 
If the frequency is within [450MHz,470MHz], the bandwidth between DL Freq Low and DL Freq High can 
be adjusted from 0.2 to 5MHz only. If the frequency is within[ 470,512], the bandwidth between DL Freq 
Low and DL Freq High can be adjusted from 0.2-3MHz. 
 
The frequency edges of two sub bands can be overlap, but they cannot be cross-contained. 
 
The total channel quantity is 32CH within 4 sub-bands. 
 
The channel center frequency must be within the frequency range of its relative sub-band, if it is not within 
the range, the system will show a reminder window to show the setting unsuccessful. 
 
If the sub band is off, all the channels belong to the sub band are auto set to off. 
 
The procedure of sub band switch on: sub band 1 is first, and then 2, 3, 4. The procedure of sub band 
switch off: sub band 4 is first, and then 3, 2, 1. And the isolation use sub band 1 to test, so make sure sub 
band 1 is always on when BDA is working. 
 
b.  Click 
 to enter to Sub Band Setting/Channel parameters setting-Class B