Table 13: RU Alarm List 
Alarm List 
Alarm Condition 
External Alarm 
 
Alarm status when the external terminals have the same H/L level with alarm 
level, otherwise normal; 
 
Alarm period: 10s by default. 
Over-Temperature 
Alarm 
 
Alarm when equipment temperature is higher than the threshold, otherwise 
normal; 
 
Alarm judgment period: 3 minutes by default; 
 
Alarm threshold : 80
℃ by default. 
Optical Tx Alarm 
 
Alarm When optical transmiting power is lower than the threshold, otherwise 
normal; 
 
Alarm judgment period: 3 minutes by default; 
 
Alarm threshold: 0dBm by default. 
Optical Rx Alarm 
 
Alarm When optical receiving power is lower than the threshold, otherwise 
normal; 
 
Alarm judgment period: 3 minutes by default; 
 
Alarm threshold: -14dBm by default. 
PA Alarm 
 
Alarm when any one of the PA Current Alarm,PA Over-temperature Alarm, 
PA DL output power overload Alarm, Reflection Power Alarm happens, 
otherwise normal; 
 
Alarm judgment period: 3 minutes by default. 
DL Output 
Overload Alarm 
 
Alarm when the DL output power is higher than the threshold, otherwise 
normal; 
 
Alarm judgment period: 3 minutes by default; 
 
Alarm threshold: 48dBm. 
Shutdown Alarm 
 
Alarm when the PA status is off, otherwise normal; 
 
Alarm judgment period: 10s by default. 
LNA Alarm 
 
Alarm when LNA have problems, otherwise normal; 
 
Alarm judgment period: 3 minutes by default. 
 
 
6.2  TROUBLESHOOTING 
Following installation and commissioning, occasional operation tasks to handle alarms may be required: 
 
Table 14: MU Alarms Diagnosis 
Alarm condition 
Diagnosis 
Over- 
Temperature 
alarm 
 
Check device temperature on WEB GUI 
 
If device temperature is over threshold, make sure environment temperature 
is within the envireonment temperature range that MU supported (0~40
℃). 
Apply climatic protection to the system under severe environment. 
Optical TX Alarm 
 
Test MU transmit optical power  
 
Replace FOU if transmit optical power is less than -7dBm 
Optical RX Alarm 
 
Use Optical Power Meter to test received optical power 
 
If received optical power is lower than -10dBm, test whether RU transmit 
optical power is normal (3~5dBm) 
 
Check if optical loss of fiber link is higher than 6.5dBo 
 
Clean fiber connector with absolute ethanol
 
 
DL Input Power 
Overload Alarm  
Test DL input power of MU, if it is higher than +33dBm, choose proper coupler to 
ensure the input power to MU is lower than +33dBm.