Comba Telecom Ltd. COMFLEX-6Q00 Manual De Usuario

Descargar
Página de 70
USER MANUAL FOR COMFLEX-6Q00 5W 
ENU STATUS: 1-0-1 
Copyright - refer to title page 
Page 17 
 
3.2 
SITE PLANNING CONSIDERATIONS 
3.2.1  SITE PLANNING 
Site Considerations 
 
The  MU  is  designed  to  be  located  indoors  to  facilitate  coupling  of  BTS  signals  and  power  supply 
connections. The input range of MU RF unit is 10~30 dBm.  
 
The site consideration for RU is listed below: 
 
 
The  distance  between  the  service  antenna  of  RU  and  coverage  area  should  satisfy  line  of  sight 
requirements for maximum coverage area. 
 
The maximum fiber length is 8 miles, with a maximum path loss of 6.5dBo. 
 
The system delay of the optical system must be taken into consideration when there are neighboring 
BTS sites overlapping in coverage. 
 
 
Installation Location 
 
Mounting surface shall be capable of supporting the weight of the equipment. 
 
In order to avoid electromagnetic interference, a proper mounting location must be selected to minimize 
interference from electromagnetic sources such as large electrical equipment. 
 
 
Environmental 
 
Humidity  has  an  adverse  effect  on  the  reliability  of  the  equipment.  It  is  recommended  to  install  the 
equipment in locations having stable temperature and unrestricted air-flow.  
 
The installation location for the system should be well ventilated. The equipment has been designed to 
operate at the temperature range and humidity level as stated in the product specifications. 
 
 
Powering  
 
The  power  supply  unit  (PSU)  provides  power  to  all  modules  within  the  equipment.  Depending  on  the 
product  variant,  it  is  recommended  that  the  PSU  operates  on  a  dedicated  AC  circuit  breaker  or  fused 
circuit. 
 
 
Grounding Requirement 
 
Verify that the equipment has been well grounded. This includes antennas and all cables connected to 
the system. Ensure lightning protection for the antennas is properly grounded.  
 
 
Cable Routing 
 
Depending on  equipment  configuration,  a  variety  of  types of cables  are connected  to  the MU and  RU: 
coaxial  cables,  optical  fibers,  power  cable,  communication  cable,  and  commissioning  cable.  Where 
applicable, ensure cables are properly routed and secured so that they are not damaged.